Page 14
Translation of the original instructions with assembly instructions AF 113 G3, Filtration Group GmbH, 23.01.18, Mat. No. 70310590, Version 07
15.2 Removing the filter insert
DANGER!
The automatic filter is pressurised!
Risk of injury to persons or damage to property
•
Make sure that the pipe is depressurised prior to
opening the automatic filter.
The numbers indicated in parentheses
correspond to those used in the spare parts
drawing.
1
•
Make sure that the pipe is depressurised prior to opening
the automatic filter.
•
Close the filter inlet and outlet.
2
•
Open the drain valve.
•
Open the vent screw.
The automatic filter is discharged.
3
•
Turn off the compressed air supply.
4
•
Switch OFF the main switch.
•
Disconnect the gear motor.
1
2
bar
kPa
psi
R
P
S
R
P
S
A
B
A
B
Fig. 12:
Disconnecting the automatic filter
5
•
Loosen and remove the hexagon screws (3.3) and the
spring washers (3.4) on the bell housing of the gear
motor.
•
Withdraw the gear motor (1) vertically from the shaft.
Fig. 13:
Removing the gear motor
6
•
Loosen and remove the hexagon screws (5) and the
washer (6) on the filter cover.
Fig. 14:
Loosening and removing the hexagon screws
on the filter cover
7
•
Apply a large screwdriver to the notch.
•
Lever off the filter cover.
3
1 1
2
4
2