Page 13
Translation of the original instructions with assembly instructions AF 113 G3, Filtration Group GmbH, 23.01.18, Mat. No. 70310590, Version 07
15
Maintenance
DANGER!
Explosion hazard!
Risk of injury to persons or damage to
property.
•
Work is only allowed to be carried out in
hazardous areas if appropriate safety
precautions are implemented.
•
Safety precautions must be implemented
by the owner.
WARNING!
If the system is maintained by unauthorised persons
Risk of injury
All warranty claims are rendered invalid
•
The system must be maintained by a suitably trained
person!
Before all maintenance work:
•
Shut down the automatic filter (section 12).
•
Take steps to prevent the machine/system from being
switched on again by unauthorised persons.
•
Wear protective clothing and equipment appropriate to
the hazard potential of the medium (e.g. goggles,
respirator, protective clothing, etc.).
•
Carry out the maintenance work.
•
Start up the automatic filter again (section 10).
15.1 Inspection and maintenance schedule
•
Refer also to the contract documentation.
Interval
Component
Activity
Weekly
Automatic filter
Check for leakage
Check the differential
pressure
Pipes
Clean
Monthly
Segmented element
Check for wear and if
necessary clean
Backflush channel
moulding z
Check for wear and if
necessary clean
Automatic filter
Check the
conductivity between
all components.
Note the maximum
permissible
resistance: R < 10
Ω
Yearly or
when
cooling
lubricant
replaced
Bearings
Check the clearance
Valves
Check correct
functioning
Segmented element
Clean
Automatic filter
Clean
Seal kit
Check for leakage
The necessary maintenance work is
dependent on the particular application.
Please consult the manufacturer if necessary.