Flowserve IPS-Beacon VB-105 Installation Operation & Maintenance Download Page 6

 

 

IPS BEACON ENGLISH  26999949  03-13 

Page 6 of 16

 

flowserve.com

 

Table 1: IPS Beacon factory default settings 

Parameter 

Default setting 

(metric units) 

Default setting 

(US units) 

X-axis vibration 
alarm level 

9.4 mm/s 

0.38 in./sec 

Y-axis vibration 
alarm level 

9.4 mm/s 

0.38 in./sec 

Z-axis vibration 
alarm level 

9.4 mm/s 

0.38 in./sec 

Temperature 
alarm level 

85 °C 

185 °F 

Vibration 
readings type 

RMS 

Data log interval 

5 minutes 

Average number 
of readings for 
alarm limit 

2 readings 

See section 5, 

Custom configuration programming

, to 

change any of the above settings. 
 

3.2  Alarm mode 

By default the IPS Beacon enters alarm mode when 
the average of two readings, of either vibration or 
temperature, exceed the predefined alarm limits.  
Alarm mode is indicated with a flashing red light.  The 
user should do a physical detailed analysis of the 
equipment being monitored when the alarm is 
activated.  (See Table 2

: LED indicator lights 

description with PUM 

installed.

 

Table 2: LED indicator lights description with 
PUM installed 

LED 

State 

Description 

GREEN 

3 quick 
flashes 

Indicates that IPS Beacon has been 
powered on 

GREEN 

Flash every 
5 seconds 

Normal operation – vibration and 
temperature are within acceptable limits 

RED 

Flash every 
5 seconds 

Current alarm – one of the 
measurements has exceeded its alarm 
limit and has not returned within the 
acceptable range 

RED & 
GREEN 

Flash every 
5 seconds 

Alarm – one of the measurements 
previously exceeded its alarm limit, but has 
now returned within the acceptable range 

 

3.3  Performance and operation limits 

This product has been selected to meet the 
specification of your purchase order. 
 
The following data is included as additional 
information to help with your installation.  This is 
typical information and if required, a definitive 
statement for your application can be obtained from 
Flowserve. 
 

3.3.1  IPS Beacon nomenclature 

 

Table 3: IPS Beacon nomenclature 

Flowserve 
item code 

Generic 
designation 

Specifications 

Material 

9050 

VB-105 

IPS Beacon compact 
monitor 

316L SS 

 

Fastener 

M6 (¼ - 28) 

18-8 

 

This product must not be operated 

beyond the parameters specified for the application.  
If there is any doubt as to the suitability of the product 
for the application intended, contact the manufacturer 
for advice. 

 IPS Beacon material compatibility is 

the responsibility of the end user. 
 

3.3.2  Sensor specifications 

 

Table 4: IPS Beacon and sensor specifications 

IPS Beacon components 

Channels (internal) 

1-battery voltage, 1-onboard 
temperature, 3-vibration (X, Y, Z) 

Measurement rates 

1 to 60 minutes 

Ambient temperature 

-40 °C (-40 °F) to +85 °C (185 °F) 

Power requirement 

3.6 VDC internal battery pack 

Outer shell 

316LSS with Borosilicate glass lens 

Mounting 

M6 (¼ x 28) stud mount 

IPS Beacon sensor components 

Variable 

Limit 

Vibration (velocity) 

Tri axis 0-25 mm/s (0 – 1 IPS) peak or 
RMS.  Ac/- 10 % full scale 

Surface temperature (T

s

measurement range 

-40 °C (-

40 °F) ≤ T

≤ +93.33 °C (200 

°F).  Ac/-2.8 °C (5 °F) 

IPS Beacon 

operational state 

Battery life 

Normal operating and 
environmental conditions 

4 years with 5 minute sampling 

Alarm mode 

4 years 

Note:  Measurement accuracy for surface temperature (range -40 to 
93.33 °C) and vibration (range 0 to 25 mm/s) is absolute accuracy of 
the measurement relative to a known, calibrated device.  Values 
shown represent the expected performance operating under steady 
state conditions at 23 °C (73 °F) with no external interferences.

 

Note: The IPS Beacon temperature measurement is optimized for 
surface temperature readings of an operating bearing housing. 

 

3.3.3  Battery 

 The IPS Beacon battery is not 

replaceable. 

You must replace the entire unit once the battery runs 
out of power.  The battery life is not covered as part 
of the standard device warranty.  Table 4 shows the 
average battery life under normal and alarm mode 
operating conditions. 
 

Summary of Contents for IPS-Beacon VB-105

Page 1: ...eration Maintenance Condition monitoring and alert system for vibration and temperature PCN 26999949 03 13 E Original instructions These instructions must be read prior to installing operating using a...

Page 2: ...ake away memory module TAM 7 4 MAINTENANCE 7 4 1 Tools required 7 4 2 Turning unit on off 7 4 3 Low battery 7 5 CUSTOM CONFIGURATION PROGRAMMING 7 5 1 User configurable settings 7 5 2 Connecting to IP...

Page 3: ...ty aspects relating to machinery and equipment and the satisfactory provision of technical documents and safety instructions Where applicable this document incorporates information relevant to these D...

Page 4: ...g Always coordinate repair activity with operations and health and safety personnel and follow all plant safety requirements and applicable safety and health laws and regulations 1 6 3 Safety action T...

Page 5: ...organic and do not represent environmental hazards once the decomposition or neutralization process has terminated Disposal in Europe Batteries for disposal should not be transported by air For road t...

Page 6: ...ication can be obtained from Flowserve 3 3 1 IPS Beacon nomenclature Table 3 IPS Beacon nomenclature Flowserve item code Generic designation Specifications Material 9050 VB 105 IPS Beacon compact moni...

Page 7: ...ollow the power up procedure below To power up the IPS Beacon simply install the PUM to the DB9 on the side of the unit and insert the screw into the PUM tighten screw to 0 7 Nm 6 in lb torque to keep...

Page 8: ...8 Parts List and Drawings for the Flowserve part number to obtain one For details on connection to the Dock refer to the Dock IOM PCN 26999975 5 3 Setting alarm set points The IPS Beacon unit can have...

Page 9: ...IPS BEACON ENGLISH 26999949 03 13 Page 9 of 16 flowserve com Figure 3 X Y Z axis orientation Figure 4 IPS Beacon drawing Figure 5 IPS Beacon mounting pad X Y Z...

Page 10: ...d through the IPS Beacon and threaded into the tap Attach IPS Beacon 9050 to bearing housing 3200 using Phillips head fastener M6 or in x 28 18 8SS stud An alternative is to attach the IPS Beacon to t...

Page 11: ...IPS Beacon to a threaded tap VB 105 screw Cap screw to attach PUM or TAM to IPS Beacon VB 101 Dock Programming dock to connect IPS Beacon to PC and change configuration settings DockTalk Configuration...

Page 12: ...n of the unit or improper installation looseness Unit configuration incorrect If the inaccurate missing data problem is across all sensor data parameters reload the original configuration for the IPS...

Page 13: ...his Declaration refers are in compliance with the Directives and Norms specified herein ATEX Directive 94 9 EC all amendments Basis for compliance The equipment has been assessed using the following s...

Page 14: ...emonstrate that the product meets the requirements of the Directives has been compiled by the signatory below and is available for inspection by the relevant enforcement authorities Signed ___________...

Page 15: ...IPS BEACON ENGLISH 26999949 03 13 Page 15 of 16 flowserve com Notes...

Page 16: ...da Flowserve Corporation 5215 North O Connor Blvd Suite 2300 Irving Texas 75039 5421 USA Telephone 1 972 443 6500 Fax 1 972 443 6800 Europe Middle East Africa Flowserve Worthington S r l Via Rossini 9...

Reviews: