Flowserve IPS-Beacon VB-105 Installation Operation & Maintenance Download Page 3

 

 

IPS BEACON ENGLISH  26999949  03-13 

Page 3 of 16

 

flowserve.com

 

1

  

INTRODUCTION

 

AND

 

SAFETY 

 

1.1  General 

 

These instructions must always be kept 

close to the product's operating location or 
directly with the product.

 

 
Flowserve products are designed, developed and 
manufactured with state-of-the-art technologies in 
modern facilities.  The unit is produced with great 
care and commitment to continuous quality control, 
utilizing sophisticated quality techniques, and safety 
requirements. 
 
Flowserve is committed to continuous quality 
improvement and being at your service for any further 
information about the product in its installation and 
operation or about its support products, repair and 
diagnostic services. 
 
These instructions are intended to facilitate 
familiarization with the product and its permitted use.  
Operating the product in compliance with these 
instructions is important to help ensure reliability in 
service and avoid risks.  The instructions may not 
take into account local regulations; ensure such 
regulations are observed by all, including those 
installing the product.  Always coordinate repair 
activity with operations personnel, and follow all plant 
safety requirements and applicable safety and health 
laws and regulations. 

 

These instructions must be read prior to 

installing, operating, using and maintaining the 
equipment in any region worldwide.  The 
equipment must not be put into service until all 
the conditions relating to safety, noted in the 
instructions, have been met.  Failure to follow and 
apply the present user instructions is considered 
to be misuse.  Personal injury, product damage, 
delay or failure caused by misuse are not covered 
by the Flowserve warranty. 

 

1.2  CE Marking and approvals 

It is a legal requirement that machinery and 
equipment put into service within certain regions of 
the world shall conform with the applicable CE 
Marking Directives covering Machinery and, where 
applicable, Low Voltage Equipment, Electromagnetic 
Compatibility (EMC), Pressure Equipment Directive 
(PED) and Equipment for Potentially Explosive 
Atmospheres (ATEX). 
 
Where applicable, the Directives and any additional 
Approvals, cover important safety aspects relating to 

machinery and equipment and the satisfactory provision 
of technical documents and safety instructions.  Where 
applicable this document incorporates information 
relevant to these Directives and Approvals. 
 
To confirm the Approvals applying and if the product is 
CE marked, check the serial number plate markings 
and the Certification.  (See section 9, 

Certification

.) 

 

1.3  Disclaimer 

Information in these User Instructions is believed to 
be complete and reliable.  However, in spite of all of 
the efforts of Flowserve Corporation to provide 
comprehensive instructions, good engineering and 
safety practice should always be used.
 

 
Flowserve manufactures products to exacting 
International Quality Management System Standards 
as certified and audited by external Quality Assurance 
organizations.  Genuine parts and accessories have 
been designed, tested and incorporated into the 
products to help ensure their continued product quality 
and performance in use.  As Flowserve cannot test 
parts and accessories sourced from other vendors the 
incorrect incorporation of such parts and accessories 
may adversely affect the performance and safety 
features of the products.  The failure to properly select, 
install or use authorized Flowserve parts and 
accessories is considered to be misuse.  Damage or 
failure caused by misuse is not covered by the 
Flowserve warranty.  In addition, any modification of 
Flowserve products or removal of original components 
may impair the safety of these products in their use. 
 

1.4  Copyright 

All rights reserved.  No part of these instructions may 
be reproduced, stored in a retrieval system or 
transmitted in any form or by any means without prior 
permission of Flowserve. 
 

1.5  Duty conditions 

This product has been selected to meet the specifications 
of your purchase order.  The acknowledgement of these 
conditions has been sent separately to the Purchaser.  A 
copy should be kept with these instructions. 

 

The product must not be operated beyond 

the parameters specified for the application.  If 
there is any doubt as to the suitability of the 
product for the application intended, contact 
Flowserve for advice. 

 
If the conditions of service on your purchase order are 
going to be changed (for example liquid pumped, 
temperature or duty) it is requested that the user seeks 
the written agreement of Flowserve before start up. 

 

Summary of Contents for IPS-Beacon VB-105

Page 1: ...eration Maintenance Condition monitoring and alert system for vibration and temperature PCN 26999949 03 13 E Original instructions These instructions must be read prior to installing operating using a...

Page 2: ...ake away memory module TAM 7 4 MAINTENANCE 7 4 1 Tools required 7 4 2 Turning unit on off 7 4 3 Low battery 7 5 CUSTOM CONFIGURATION PROGRAMMING 7 5 1 User configurable settings 7 5 2 Connecting to IP...

Page 3: ...ty aspects relating to machinery and equipment and the satisfactory provision of technical documents and safety instructions Where applicable this document incorporates information relevant to these D...

Page 4: ...g Always coordinate repair activity with operations and health and safety personnel and follow all plant safety requirements and applicable safety and health laws and regulations 1 6 3 Safety action T...

Page 5: ...organic and do not represent environmental hazards once the decomposition or neutralization process has terminated Disposal in Europe Batteries for disposal should not be transported by air For road t...

Page 6: ...ication can be obtained from Flowserve 3 3 1 IPS Beacon nomenclature Table 3 IPS Beacon nomenclature Flowserve item code Generic designation Specifications Material 9050 VB 105 IPS Beacon compact moni...

Page 7: ...ollow the power up procedure below To power up the IPS Beacon simply install the PUM to the DB9 on the side of the unit and insert the screw into the PUM tighten screw to 0 7 Nm 6 in lb torque to keep...

Page 8: ...8 Parts List and Drawings for the Flowserve part number to obtain one For details on connection to the Dock refer to the Dock IOM PCN 26999975 5 3 Setting alarm set points The IPS Beacon unit can have...

Page 9: ...IPS BEACON ENGLISH 26999949 03 13 Page 9 of 16 flowserve com Figure 3 X Y Z axis orientation Figure 4 IPS Beacon drawing Figure 5 IPS Beacon mounting pad X Y Z...

Page 10: ...d through the IPS Beacon and threaded into the tap Attach IPS Beacon 9050 to bearing housing 3200 using Phillips head fastener M6 or in x 28 18 8SS stud An alternative is to attach the IPS Beacon to t...

Page 11: ...IPS Beacon to a threaded tap VB 105 screw Cap screw to attach PUM or TAM to IPS Beacon VB 101 Dock Programming dock to connect IPS Beacon to PC and change configuration settings DockTalk Configuration...

Page 12: ...n of the unit or improper installation looseness Unit configuration incorrect If the inaccurate missing data problem is across all sensor data parameters reload the original configuration for the IPS...

Page 13: ...his Declaration refers are in compliance with the Directives and Norms specified herein ATEX Directive 94 9 EC all amendments Basis for compliance The equipment has been assessed using the following s...

Page 14: ...emonstrate that the product meets the requirements of the Directives has been compiled by the signatory below and is available for inspection by the relevant enforcement authorities Signed ___________...

Page 15: ...IPS BEACON ENGLISH 26999949 03 13 Page 15 of 16 flowserve com Notes...

Page 16: ...da Flowserve Corporation 5215 North O Connor Blvd Suite 2300 Irving Texas 75039 5421 USA Telephone 1 972 443 6500 Fax 1 972 443 6800 Europe Middle East Africa Flowserve Worthington S r l Via Rossini 9...

Reviews: