EchoSwitch II
09 JUL 08
MN300650
Rev
A
How to enter the MENU
1.
Press and hold SELECT key (approximately 5 seconds) until MENU is displayed.
2.
The menu items will rotate through display.
3.
Press SELECT to change an item.
How to configure UNITS
1.
In the MENU mode, press select when UNITS is display.
2.
Press SELECT to choose between INCHES, CM (centimeter), FEET, METERS or
PERCENT.
3.
Select EXIT to return to the Top Level Menu.
Note: Reading the level of liquid in Percent
•
Flowline recommends that when selecting PERCENT, configure the Height and Fill_H
settings before selecting PERCENT in order to span the EchoSwitch II for your
application requirements.
•
When in PERCENT, the operational span will be based upon the last TANK settings,
typically the factory settings for Height and Fill_H.
EchoSwitch II
Height
Fill_H
LU77 Series
98.4” (250 cm)
94.4” (239.8 cm)
LU78 Series
295.2” (750 cm)
287.2” (729.7 cm)
•
When PERCENT is selected, the TANK settings (Height and Fill_H) will be disabled.