E. Programming HEIGHT:  

To change HEIGHT 4 mA value.

1.  Press the SELECT/FAST button and hold it for 5 seconds until 

MENU appears.

2.  When TANK appears, press the SELECT/FAST button. The dis-

play will rotate between HEIGHT, FILL H and EXIT.

3.  When  HEIGHT  appears,  press  the  SELECT/FAST  button.  The 

display will show a decimal reading in the selected UNITS. 

4.  Press the UP/DOWN buttons to increase or decrease this value. This 

value is the distance from the transducer face to the bottom of the tank.  

NOTE:  Simultaneously  holding  down  the  SELECT/FAST  button 

while pressing the UP or DOWN button will increase the speed of the 

display. 

5.  When you have reached the desired value, press SELECT/FAST 

to SAVE.

You have successfully programmed the HEIGHT or 4 mA value.

F. Programming FILL H:

 To change FILL H 20 mA value.

1.  Press the SELECT/FAST button and hold it for 5 seconds until 

MENU appears.

2.  When TANK appears, press the SELECT/FAST button. The dis-

play will rotate between HEIGHT, FILL H and EXIT.

3.  When  FILL  H  appears,  press  the  SELECT/FAST  button.  The 

display will show a decimal reading in the selected UNITS. 

4.  Press the UP/DOWN buttons to increase or decrease this value. This 

value is the distance from the bottom of the tank to the full point 

(typically the straight wall height). 

5.  When you have reached the desired value, press SELECT/FAST 

to SAVE it.

You have successfully programmed the FILL H or 20mA value.

Step Nine

C. Programming UNITS:

  To change UNITS from INCHES to 

CM or PERCENT.  

1.  Press the SELECT/FAST button and hold it for 5 seconds until 

MENU appears.

2.  When  UNITS  appears,  press  the  SELECT/FAST  button. The  dis-

play  will  rotate  between  INCHES,  CM,,  FT,  M,  PERCENT  and 
DISPLAY.  

3.  Press  the  SELECT/FAST  button  when  the  UNITS  you  want 

(INCHES, CM, FT, M or PERCENT) appear.  The display will 
then display SAVED.  

You have successfully changed the UNITS function.

Note:  Percent units can only be selected after the trans-
mitters Height (4 mA) and Fill H (20 mA) set points have 
been programmed. Therefore initial programming should 
always be done in INCH, CM, FT or M UNITS. 

D.  Programming  Off  Tank:

  If you know the dimensions of 

your tank, you may input the 4 mA and 20 mA set points manually.   

To do so, review the following: 

HEIGHT:

 The point in inches or centimeters from the transducer 

face where the output will be 4 mA (generally the bottom of the 

tank). Factory default is the same as the unit’s maximum range. 

Example XP88 = 295” maximum range which is also the same 4 

mA set point under factory default.

FILL H:

 The point in inches or centimeters from the bottom of the 

tank to the high level where the output will be 20 mA (generally 

the straight wall distance from the bottom of the tank). NOTE: The 

transmitter dead band is automatically subtracted from the FILL H. 

Example: XP88 = 8” dead band. Therefore the maximum FILL H 

is 295” [maximum range] - 8” [dead band] = 287”.

Step Eight

PROGRAMMING

PROGRAMMING

SELECT

FAST

SELECT

FAST

MENU

EchoSafe

EchoSafe

HEIGHT

(MaxR)

EMPTY

FULL

FILL H

(MinR)

SELECT

FAST

SELECT

FAST

SELECT

FAST

UP

DOWN

0HQX

SELECT

FAST

SELECT

FAST

SELECT

FAST

UP

DOWN

0HQX

Summary of Contents for EchoSafe XP88

Page 1: ...duct returned to Flowline where a There is evidence of a potentially hazardous material present with product b The product has remained unclaimed at Flowline for longer than 30 days after dutifully requesting disposition of the product THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY This warranty and the obligations and liabilities of Flowline under it are ...

Page 2: ...lay type Display units Memory Supply voltage Loop resistance Signal output Signal invert Calibration Fail safe Process Temp Temp comp Electronics temp Pressure Enclosure rating Enclosure mat Window mat Transducer mat Process mount Conduit entrance Compliance Classification Approvals XP88 8 to 24 6 20 cm to 7 5 m XP89 8 to 32 8 20 cm to 10 m 0 2 of max range 0 079 2 mm 3 7 6 cm dia XP88 8 20 cm XP9...

Page 3: ...hin the fitting Always check for leaks prior to system start up Opening The Enclosure EchoSafe is designed to be installed in a hazardous areas and when installed do not open the unit while power is applied Always disconnect the power source from EchoSafe prior to opening programming install ing or removing it Additionally ensure that electrical wiring fittings and mechanical connections conform t...

Page 4: ...ammed FULL set point C EMPTY Level has reached the programmed EMPTY set point D UNITS Selectable in inches centimeters feet meter or percent The factory default is Inches E INCHES Inch units of measurement F CM Centimeters units of measurement G FEET Feet units of measurement H METERS Meter units of measurement I PERCNT 0 100 units of measurement Percent is the calcu lated value based on the 4mA a...

Page 5: ...olding down the SELECT FAST button while pressing the UP or DOWN button will increase the speed of the display Step Seven PROGRAMMING A Introduction The transmitter has two modes RUN and MENU In the RUN mode the transmitter is operational and the dis play will indicate the liquid height in inches centimeters or percent In the MENU mode the display will indicate the selected mode of calibration The...

Page 6: ...g UNITS To change UNITS from INCHES to CM or PERCENT 1 Press the SELECT FAST button and hold it for 5 seconds until MENU appears 2 When UNITS appears press the SELECT FAST button The dis play will rotate between INCHES CM FT M PERCENT and DISPLAY 3 Press the SELECT FAST button when the UNITS you want INCHES CM FT M or PERCENT appear The display will then display SAVED You have successfully changed...

Page 7: ...e to the HEIGHT value will result in an equal increase to the FILL H value A decrease to the HEIGHT value will result in an equal decrease to the FILL H value Step Eleven PROGRAMMING EchoSafe EchoSafe 4 mA 20 mA 20 mA 4 mA SELECT FAST SELECT FAST SELECT FAST 0HQX 7 EchoSafe 20 mA 4 mA Normal mA Mode 4 mA set at empty tank and 20 mA set at full tank Reverse mA Mode 20 mA set at empty tank and 4 mA ...

Page 8: ...Do not install within 3 of tank side wall Do not install with objects in the beam Do not install in applications with vacuum EchoSafe Dead Band Ventilation Hole Operational Range Highest Liquid Level Lowest Liquid Level 3 Minimum Diameter EchoSafe Warning Flowline Ultrasonic transmitters have been optimized for use in non metallic fittings For best performance avoid the use of metal fittings Insta...

Page 9: ...T FAST SELECT FAST SELECT FAST 0 18 7 7 TROUBLESHOOTING Transmitter XP88 0 XP89 0 4 mA Setting 26 4 7 5m 32 8 10m 20 mA Setting 8 20 cm 12 30 cm Factory Set Points Power Supply Power Supply 20 mA 4 mA mA 4 5 6 mA 19 20 21 Black Red EchoSafe EchoSafe Black Red TROUBLESHOOTING A Viewing Programmed VALUES 1 Press the SELECT FAST button and hold it for 5 seconds until MENU appears 2 When HELP appears ...

Reviews: