FlowLine EchoSafe XP88 Owner'S Manual Download Page 2

Step One

SPECIFICATIONS

40

30

 

20

 10

 00

-40

-20

00

20

40

60

80

Acceptable

Range

Unacceptable

Range

Temperature/Pressure Derating

Operating Pressure (psi)

Temperature (  C)

800 

600 

400 

200

0

12          16           20          24          28

Acceptable

Range

Unacceptable

Range

Maximum Loop Resistance

M

ax

. S

er

ie

R

es

is

ta

nc

(O

hm

s)

Supply Voltage (VDC)

Maximum Temperature/Voltage

Derating @ Continuous 20 mA

A

m

bi

en

t S

en

so

r T

em

pe

ra

tu

re

 (

  C

)

Operating Voltage (VDC)

100 

80 

60 

40 

20 

0

Acceptable

Range

Unacceptable

Range

12          16           20          24          28

4.44" (11.3 cm)

4.00"

(10.2 cm)

6.06"

15.4 cm

PRELIMINARY XP HOUSING 

OVERALL DIMENSIONS

6.06" (15.4 cm)

3.89" (9.9 cm)

2" NPT

UP

DOWN

SELECT

FAST

EchoSafe

1/2" NPT

Top View 

4.44" (11.3 cm)

4.00"

(10.2 cm)

6.06"

15.4 cm

PRELIMINARY XP HOUSING 

OVERALL DIMENSIONS

6.06" (15.4 cm)

3.89" (9.9 cm)

2" NPT

UP

DOWN

SELECT

FAST

EchoSafe

1/2" NPT

Side View 

4.44" (11.3 cm)

4.00"

(10.2 cm)

6.06"

15.4 cm

PRELIMINARY XP HOUSING 

OVERALL DIMENSIONS

6.06" (15.4 cm)

3.89" (9.9 cm)

2" NPT

UP

DOWN

SELECT

FAST

EchoSafe

1/2" NPT

Front View 

Range:

Accuracy:
Resolution:
Beam width:
Dead band:

Display type:
Display units:
Memory:
Supply voltage:
Loop resistance:
Signal output:
Signal invert:
Calibration:
Fail-safe:
 
Process Temp.:

Temp. comp.:
Electronics temp.:

Pressure:
Enclosure rating:
Enclosure mat.:
Window mat.:
Transducer mat.:
Process mount:
Conduit entrance:
Compliance:
Classification:
Approvals:

XP88: 8" to 24.6'
(20 cm to 7.5 m)
XP89: 8" to 32.8'
(20 cm to 10 m)
± 0.2% of max. range
0.079" (2 mm)
3" (7.6 cm) dia.
XP88: 8" (20 cm)
XP99: 8" (20 cm)
LCD, 6-digits
Inch, cm, ft, m, percent
Non-volatile
18-28 VDC (loop)
250

Ω

 max @ 24 VDC

4-20 mA , two-wire
4-20 mA or 20-4 mA
Push button (3-button)
4 mA, 20 mA, 21 mA,
22 mA or hold last
F: -4° to 140°
C: -20° to 60°
Automatic
F: -40° to 160°
C: -40° to 71°
30 psi (2 bar)
NEMA 4
Aluminum
Glass
PVDF
2" NPT
Dual, 1/2" NPT
RoHS
Explosion proof
FM: Class 1, Div 1,
     Groups A, B, C, D
     Class II/III, Div 1,
     Groups E, F, G
     

Summary of Contents for EchoSafe XP88

Page 1: ...duct returned to Flowline where a There is evidence of a potentially hazardous material present with product b The product has remained unclaimed at Flowline for longer than 30 days after dutifully requesting disposition of the product THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY This warranty and the obligations and liabilities of Flowline under it are ...

Page 2: ...lay type Display units Memory Supply voltage Loop resistance Signal output Signal invert Calibration Fail safe Process Temp Temp comp Electronics temp Pressure Enclosure rating Enclosure mat Window mat Transducer mat Process mount Conduit entrance Compliance Classification Approvals XP88 8 to 24 6 20 cm to 7 5 m XP89 8 to 32 8 20 cm to 10 m 0 2 of max range 0 079 2 mm 3 7 6 cm dia XP88 8 20 cm XP9...

Page 3: ...hin the fitting Always check for leaks prior to system start up Opening The Enclosure EchoSafe is designed to be installed in a hazardous areas and when installed do not open the unit while power is applied Always disconnect the power source from EchoSafe prior to opening programming install ing or removing it Additionally ensure that electrical wiring fittings and mechanical connections conform t...

Page 4: ...ammed FULL set point C EMPTY Level has reached the programmed EMPTY set point D UNITS Selectable in inches centimeters feet meter or percent The factory default is Inches E INCHES Inch units of measurement F CM Centimeters units of measurement G FEET Feet units of measurement H METERS Meter units of measurement I PERCNT 0 100 units of measurement Percent is the calcu lated value based on the 4mA a...

Page 5: ...olding down the SELECT FAST button while pressing the UP or DOWN button will increase the speed of the display Step Seven PROGRAMMING A Introduction The transmitter has two modes RUN and MENU In the RUN mode the transmitter is operational and the dis play will indicate the liquid height in inches centimeters or percent In the MENU mode the display will indicate the selected mode of calibration The...

Page 6: ...g UNITS To change UNITS from INCHES to CM or PERCENT 1 Press the SELECT FAST button and hold it for 5 seconds until MENU appears 2 When UNITS appears press the SELECT FAST button The dis play will rotate between INCHES CM FT M PERCENT and DISPLAY 3 Press the SELECT FAST button when the UNITS you want INCHES CM FT M or PERCENT appear The display will then display SAVED You have successfully changed...

Page 7: ...e to the HEIGHT value will result in an equal increase to the FILL H value A decrease to the HEIGHT value will result in an equal decrease to the FILL H value Step Eleven PROGRAMMING EchoSafe EchoSafe 4 mA 20 mA 20 mA 4 mA SELECT FAST SELECT FAST SELECT FAST 0HQX 7 EchoSafe 20 mA 4 mA Normal mA Mode 4 mA set at empty tank and 20 mA set at full tank Reverse mA Mode 20 mA set at empty tank and 4 mA ...

Page 8: ...Do not install within 3 of tank side wall Do not install with objects in the beam Do not install in applications with vacuum EchoSafe Dead Band Ventilation Hole Operational Range Highest Liquid Level Lowest Liquid Level 3 Minimum Diameter EchoSafe Warning Flowline Ultrasonic transmitters have been optimized for use in non metallic fittings For best performance avoid the use of metal fittings Insta...

Page 9: ...T FAST SELECT FAST SELECT FAST 0 18 7 7 TROUBLESHOOTING Transmitter XP88 0 XP89 0 4 mA Setting 26 4 7 5m 32 8 10m 20 mA Setting 8 20 cm 12 30 cm Factory Set Points Power Supply Power Supply 20 mA 4 mA mA 4 5 6 mA 19 20 21 Black Red EchoSafe EchoSafe Black Red TROUBLESHOOTING A Viewing Programmed VALUES 1 Press the SELECT FAST button and hold it for 5 seconds until MENU appears 2 When HELP appears ...

Reviews: