WARRANTY

Flowline warrants to the original purchaser of its products that such 

products will be free from defects in material and workmanship under 

normal use and service for a period which is equal to the shorter of 

one year from the date of purchase of such products or two years from 

the date of manufacture of such products.

This warranty covers only those components of the products which 

are non-moving and not subject to normal wear. Moreover, products 

which are modified or altered, and electrical cables which are cut to 

length during installation are not covered by this warranty.

Flowline’s  obligation  under  this  warranty  is  solely  and  exclusively 

limited  to  the  repair  or  replacement,  at  Flowline’s  option,  of  the 

products  (or  components  thereof)  which  Flowline’s  examination 

proves  to  its  satisfaction  to  be  defective.  FLOWLINE  SHALL 

HAVE  NO  OBLIGATION  FOR  CONSEQUENTIAL  DAMAGES 

TO PERSONAL OR REAL PROPERTY, OR FOR INJURY TO ANY 

PERSON.

This  warranty  does  not  apply  to  products which  have  been  subject 

to electrical or chemical damage due to improper use, accident, neg-

ligence,  abuse  or  misuse. Abuse  shall  be  assumed  when  indicated 

by  electrical damage  to  relays,  reed  switches  or  other  components. 

The warranty does not apply to products which are damaged during 

shipment back to Flowline’s factory or designated service center or 

are returned without the original casing on the products. Moreover, 

this  warranty  becomes  immediately  null  and  void  if  anyone  other 

than service personnel authorized by Flowline attempts to repair the 

defective products.

Products which are thought to be defective must be shipped prepaid 

and insured to Flowline’s factory or a designated service center (the 

identity and address of which will be provided upon request) within 

30 days of the discovery of the defect. Such defective products must 

be accompanied by proof of the date of purchase.

Flowline further reserves the right to unilaterally waive this warranty 

and to dispose of any product returned to Flowline where:

a. There  is  evidence  of  a  potentially  hazardous  material  present 

with product.

b. The product has remained unclaimed at Flowline for longer than 

30 days after dutifully requesting disposition of the product.

THERE  ARE  NO  WARRANTIES  WHICH  EXTEND  BEYOND 

THE  DESCRIPTION  ON  THE  FACE  OF  THIS  WARRANTY. 

This  warranty  and  the  obligations  and  liabilities  of  Flowline  under 

it  are  exclusive  and  instead  of,  and  the  original  purchaser  hereby 

waives,  all  other  remedies,  warranties,  guarantees  or  liabilities, 

express  or  implied.  EXCLUDED  FROM  THIS  WARRANTY  IS 

THE IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS 

FOR A  PARTICULAR  PURPOSE  OR  USE AND  THE  IMPLIED 

WARRANTY OF MERCHANT ABILITY OF THE PRODUCTS.

This warranty may not be extended, altered or varied except by a writ-

ten instrument signed by a duly-authorized officer of Flowline, Inc.

To register your product with the manufacturer, go to the Flowline 

website  for  on-line  registration.    The  website  address  is  as  fol-

lows:

www.flowline.com

On-line Warranty Registration can be found under Contact Us on 

the Navigation Bar along the side of the home page. 
If for some reason your product must be returned for factory ser-

vice, contact Flowline Inc. at (562)598-3015 to receive a Material 

Return  Authorization  number  (MRA),  providing  the  following 

information:

1.  Part Number, Serial Number

2.  Name and telephone number of someone who can answer 

technical  questions  related  to  the  product  and  its  applica-

tion.  

3.  Return Shipping Address

4.  Brief Description of the Symptom

5.  Brief Description of the Application

Once you have received a Material Return Authorization number, 

ship the product prepaid in its original packing to:
 

Flowline Factory Service

 

MRA _____

 

10500 Humbolt Street

 

Los Alamitos, CA 90720

To avoid delays in processing your repair, write the MRA on the 

shipping label.  Please include the information about the malfunc-

tion with your product.  This information enables our service tech-

nicians to process your repair order as quickly as possible.

We Do Your Level Best

®

EchoSafe Explosion-Proof
Ultrasonic Level Transmitter
Model XP88 / XP89
Owner’s Manual

Version 1.1

© 2007 FLOWLINE Inc.

All rights reserved.

Manual # MN300600 B

RoHS

Compliant

Summary of Contents for EchoSafe XP88

Page 1: ...duct returned to Flowline where a There is evidence of a potentially hazardous material present with product b The product has remained unclaimed at Flowline for longer than 30 days after dutifully requesting disposition of the product THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY This warranty and the obligations and liabilities of Flowline under it are ...

Page 2: ...lay type Display units Memory Supply voltage Loop resistance Signal output Signal invert Calibration Fail safe Process Temp Temp comp Electronics temp Pressure Enclosure rating Enclosure mat Window mat Transducer mat Process mount Conduit entrance Compliance Classification Approvals XP88 8 to 24 6 20 cm to 7 5 m XP89 8 to 32 8 20 cm to 10 m 0 2 of max range 0 079 2 mm 3 7 6 cm dia XP88 8 20 cm XP9...

Page 3: ...hin the fitting Always check for leaks prior to system start up Opening The Enclosure EchoSafe is designed to be installed in a hazardous areas and when installed do not open the unit while power is applied Always disconnect the power source from EchoSafe prior to opening programming install ing or removing it Additionally ensure that electrical wiring fittings and mechanical connections conform t...

Page 4: ...ammed FULL set point C EMPTY Level has reached the programmed EMPTY set point D UNITS Selectable in inches centimeters feet meter or percent The factory default is Inches E INCHES Inch units of measurement F CM Centimeters units of measurement G FEET Feet units of measurement H METERS Meter units of measurement I PERCNT 0 100 units of measurement Percent is the calcu lated value based on the 4mA a...

Page 5: ...olding down the SELECT FAST button while pressing the UP or DOWN button will increase the speed of the display Step Seven PROGRAMMING A Introduction The transmitter has two modes RUN and MENU In the RUN mode the transmitter is operational and the dis play will indicate the liquid height in inches centimeters or percent In the MENU mode the display will indicate the selected mode of calibration The...

Page 6: ...g UNITS To change UNITS from INCHES to CM or PERCENT 1 Press the SELECT FAST button and hold it for 5 seconds until MENU appears 2 When UNITS appears press the SELECT FAST button The dis play will rotate between INCHES CM FT M PERCENT and DISPLAY 3 Press the SELECT FAST button when the UNITS you want INCHES CM FT M or PERCENT appear The display will then display SAVED You have successfully changed...

Page 7: ...e to the HEIGHT value will result in an equal increase to the FILL H value A decrease to the HEIGHT value will result in an equal decrease to the FILL H value Step Eleven PROGRAMMING EchoSafe EchoSafe 4 mA 20 mA 20 mA 4 mA SELECT FAST SELECT FAST SELECT FAST 0HQX 7 EchoSafe 20 mA 4 mA Normal mA Mode 4 mA set at empty tank and 20 mA set at full tank Reverse mA Mode 20 mA set at empty tank and 4 mA ...

Page 8: ...Do not install within 3 of tank side wall Do not install with objects in the beam Do not install in applications with vacuum EchoSafe Dead Band Ventilation Hole Operational Range Highest Liquid Level Lowest Liquid Level 3 Minimum Diameter EchoSafe Warning Flowline Ultrasonic transmitters have been optimized for use in non metallic fittings For best performance avoid the use of metal fittings Insta...

Page 9: ...T FAST SELECT FAST SELECT FAST 0 18 7 7 TROUBLESHOOTING Transmitter XP88 0 XP89 0 4 mA Setting 26 4 7 5m 32 8 10m 20 mA Setting 8 20 cm 12 30 cm Factory Set Points Power Supply Power Supply 20 mA 4 mA mA 4 5 6 mA 19 20 21 Black Red EchoSafe EchoSafe Black Red TROUBLESHOOTING A Viewing Programmed VALUES 1 Press the SELECT FAST button and hold it for 5 seconds until MENU appears 2 When HELP appears ...