FRONT PANEL OPERATION 

Display 

The display shows the units for the level or volume of the 
tank. It also displays the unit of measurement for the 
application. A graphical representation of the percent full is 
displayed along the side of the screen. 

Buttons 

Down the right side of the LI24 series front panel are four buttons. It is through these 
buttons that you will set up and configure the Loop-Powered Meter. These buttons 
are explained as follows: 

Menu

Use this button to enter or exit the Programming Mode at any time. 

Right Arrow/F1

.  Use this button to move to scroll forward through the menus, select 

digits during numeric programming, select characters during text 
programming or decrement the value of a digit or character 
selected with the Up-Arrow. 

Up Arrow/F2

Use this button to scroll backwards through the menus or to 
increment the value of a digit or character. 

ENTER/F3

.  

Use this button to access a menu or to accept a setting or 
programmed digit/character value.  

PROGRAMMING THE LOOP-POWERED METER 

To enter the LI24 series Programming menu, press the 

MENU

 button. With the 

UP

 arrow or 

RIGHT

 arrow, you 

can scroll through four menu options: Input, Output, Advanced and Display 

Input  

This selects the units of operation as well as scaling the display to the application required span. 

Output 

This configures the outputs of the LI24 series.  Depending on which version selected, not all of 
these options are available.  Outputs are open collectors, relays, 4-20mA repeater and control 
functions.  Please refer to the LI24 series Manual for further information. 

Advanced

  

This allows for all advanced features of the LI24 series to be configured.  Please refer to the 
LI24 series Manual for further information. 

Display 

This configures all features associated with the display.  Features include units, decimal point, 
comma, bar graph, top display and bottom display.  Please refer to the LI24 series Manual for 
further information. 

Summary of Contents for DataLoop LI24 Series

Page 1: ...Hu 19 Flowline Rights Reser e in USA 24 Series Data Loop Pow umbolt Street Los Inc rved s Quick S aLoo wered Met Alamitos CA 9072 IEC Start op ters 20 p 562 598 3015 CEx 5 f 562 431 8507 w flowline co...

Page 2: ...s Area Bar graph Two Solid State Relays PD6608 L5N FL LI24 1211 Loop Powered Hazardous Area Bar graph Two Solid State Relays and 4 20mA Analog Output Manufactured by Precision Digital Corporation 233...

Page 3: ...ition Safety requirements for electrical equipment for measurement control and laboratory use Additional Standards UL 50E HAZARDOUS AREA APPROVALS ATEX Certificate Number CML 17ATEX2015X 0518 Ex ia II...

Page 4: ...2 or Zone location if so approved Under certain extreme circumstances the non metallic parts incorporated in the enclosure of this equipment may generate an ignition capable level of electrostatic cha...

Page 5: ...ion installation instructions for associated apparatus barrier must be followed when installing this equipment For safe installation of an ATEX approved transmitter in series with LI24 loop powered me...

Page 6: ...clearance behind the panel for wiring Be sure to maintain a minimum panel thickness of 0 04 0 25 1 0 mm 6 4 mm to maintain type 4X rating This would equal 0 06 1 5 mm for a steel panel and 0 16 4 1 mm...

Page 7: ...light is recommended for dim lighting conditions and is enabled when wired as shown in the following diagram The backlight may be bypassed if installed in bright lighting conditions to reduce the maxi...

Page 8: ...value of a digit or character ENTER F3 Use this button to access a menu or to accept a setting or programmed digit character value PROGRAMMING THE LOOP POWERED METER To enter the LI24 series Programm...

Page 9: ...ess and hold the RIGHT Arrow button until all digits reset to zero Press the ENTER button at any time to accept a setting or MENU button to exit without saving changes Note the underscore in the graph...

Page 10: ...ace The accuracy is very good but may not be practical When selecting a decimal point take into account the practical scale for reading the level of liquid To set the Decimal Point 1 Press the MENU bu...

Page 11: ...s feet cm meter etc Please determine the units of operation that you want to appear on the display To set the Units of Operation 1 Press MENU button to bring up the SETUP Input screen 2 Press ENTER bu...

Page 12: ...inputs and corresponding display value In the examples above the 4 mA Empty reading could represent 0 Gallons 0 Feet 0 Inches or 0 0 The 20 mA Full reading could represent 5 000 Gallons 10 00 Feet 12...

Page 13: ...efault is 00100 00 and typically be the value you want to display when the tank is full b To change the value use the UP Arrow to incrementally increase the selected digit and the Right Arrow to move...

Page 14: ...This feature can be enabled or disabled using the Bargraph menu BARGRAPH The value displayed on the bar graph can be the percentage of full scale PV PCT or the percentage of a user programmable range...

Page 15: ...LIN6606QS_FL_A 02 19 QS302110A 15 This Page Intentionally Left Blank...

Page 16: ...s for which the original purchaser does not follow the warranty procedures outlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use...

Reviews: