www.flowair.com |13
5.3.4. REGULATION T-BOX – WIRING DIAGRAMS
Power supply 3x400V/50Hz
•
ELiS B-E-100 (min. 5x4 mm
2
) (Overcurrent B16)
•
ELiS B-E-150 (min. 5x6 mm
2
) (Overcurrent B20)
•
ELiS B-E-200 (min. 5x6 mm
2
) (Overcurrent B25)
T-box (LIYCY 4x0,5mm
2
A and B braided wire pair max. 50 m
Door contact DCe/DCm (door closed – contacts opened; door opened – contacts closed)
ATTENTION:
Switch 4 on SW3 to the position “E” and then restart the system switching it off for 5 seconds. Each time the device is switched
off the heaters are being cooled for next 15 seconds.
5.3.5. CONTROL SYSTEM - MASTER-SLAVE COMMUNICATION
Electrical air curtain chaining provides control from 1 to 5 devices using one T-box or TS.
Electrical air curtain chaining might be done by cable OMY 3x0,5mm
2
using connectors EL-B; EL-A, GND
Connecting units among themselves ensure transfer of controlling signals. Whatever each
curtain need to be supplied directly.
Switch 2 on SW3 set In position:
– For MASTER curtain
– For SLAVE curtain