Periodic maintenance
Daily inspections and periodic maintenance will help
you get the maximum life, safety, and efficiency from
your FLOW equipment. Periodic maintenance is regu-
larly scheduled preventive maintenance and includes
replacing worn parts that have reached the end of their
service life. It will help minimize unscheduled down
time, maximize equipment use, and eliminate unsafe
operating conditions.
Flow recommends that you use a maintenance and ser-
vice log to record all service work. Maintenance Log
MS-2258 is provided on the CD.
Note:
Review all maintenance precautions and safety
instructions listed in the intensifier pump manual.
Maintenance tips
•
Stock enough spare parts to minimize downtime
and help avoid rush part orders.
•
Practice good housekeeping.
•
Assign a complete set of service tools to the
workstation.
Maintenance precautions
•
Protect all machined and lapped mating surfaces
from damage.
•
Carefully work out any damage to seal surfaces, or
seal damage and leaks will be a recurring problem.
•
Carefully clean and blow out all parts being reas-
sembled. Do not use paper towels.
•
Do not use any substitutes for the sealants and lu-
bricants recommended by Flow.
Torque specifications
Refer to the following table when specific torque re-
quirements are not listed in a service procedure.
Mounting bolts and machine screws shall not be
torqued beyond the manufacturer’s recommended
limits.
High-pressure
gland nuts
U.S.
(ft-lb)
SI
(N-m)
1
4
in.
15-25
20-34
3
8
in.
35-45
47-60
9
16
in.
60-75
80-100
Note:
Before assembly, lubricate threads of all
high-pressure tubing connections with Blue Lubricant.
6 | M-310
© Flow International Corporation
ESL Intensifier