5. Set the end cap aside. Flow recommends that you
service the check valves at every regular seal re-
placement interval, following the procedure in
End
Cap and Check Valve
.
When the check valve service is complete, continue
with Step 6.
6. Loosen the high-pressure cylinder using a girth or
strap wrench.
CAUTION
DO NOT grip the cylinder with any sharp-toothed tool.
Surface scratches and gouges will lead to early part failure.
7. Remove the cylinder by hand,
carefully
sliding it off
the plunger to avoid scoring the plunger or the seal
backup sleeve (located inside the cylinder).
8. Use the seal tool to remove the high-pressure seals
from the cylinder. Check the seals for flaws and re-
place as needed.
High-pressure seal tool kit