Warning and shutdown conditions
1. Low inlet water pressure (warning and shutdown)
Filters are dirty
Replace 0.5 and/or 1 micron inlet water filters.
Inlet water turned off or incoming wa-
ter supply interrupted
Inspect supply valves and hoses.
2. High hydraulic oil temperature (warning and shutdown)
Incorrectly adjusted cooling circuit
Adjust cooling water flow control valve on pump bulkhead.
Faulty heat exchanger
Inspect and replace heat exchanger.
Damaged intensifier low-pressure
cylinder
Refer to manual M-376, Hyperpressure™ Intensifier
3. High check valve temperature (warning)
Worn check valve
See
Servicing the check valve
in manual M-376,
94K Hyperpressure™ Intensifier
Fractured check valve body
See
Servicing the check valve
in manual M-376,
94K Hyperpressure™ Intensifier
Fractured outlet check valve seat
See
Servicing the check valve
in manual M-376,
94K Hyperpressure™ Intensifier
Damaged outlet check valve poppet
See
Servicing the check valve
in manual M-376,
94K Hyperpressure™ Intensifier
4. High bleed-down valve temperature (warning)
Worn bleed-down valve
See
Servicing the bleed-down valve
Worn or damaged bleed-down valve
poppet and or seat
See
Servicing the bleed-down valve
Fractured bleed-down valve seat
See
Servicing the bleed-down valve
5. Low hydraulic oil level (shutdown)
Oil level in reservoir is low.
Check for leaks; add hydraulic oil.
Note
: Make sure the oil level is between the high level mark and the top edge of the
indicator glass. An oil shutdown will occur approximately 1 in. below the high level
mark.
6. Intensifier motor overload (shutdown)
Incoming voltage is low on one or
more 3-phase legs.
Check plant power supply.
Motor starter failure.
Check operation of contactor; replace if necessary.
Hydraulic pump is seized or bound.
Inspect hydraulic pump.
Motor is faulty.
Replace if necessary.
© Flow International Corporation
M-390 | 39
CHAPTER 4
Maintenance & Troubleshooting
Summary of Contents for 94i-D
Page 1: ...HYPERJET 94i S 94i D M 390 REV C APRIL 2010 ...
Page 6: ...Notes 6 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...
Page 20: ...Notes 20 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...
Page 30: ...Notes 30 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...
Page 40: ...Notes 40 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...
Page 75: ...CHAPTER 7 Customer Support MS 2266 Customer Support Flow International Corporation M 390 75 ...
Page 76: ...Notes 76 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...