Electrical / Operation

3

Piping – Effluent Applications
(3/4" or Less Solids)

Piping must be 1-1/2" minimum to carry volume of
pump discharge. Check local codes to determine if a
check valve is required in your system. In cold climates,
check valves are not used to prevent effluent from
freezing in piping.

Piping – Sewage Applications 
(2" or Less Solids)

In any case, piping must not be smaller than pump 
discharge.

When installed in a sewage system, pipe must be capable
of handling semi-solids of at least 2" (5.1 cm) diameter.

The rate of flow in the discharge pipe must keep any
solids present in suspension in the fluid. To meet
minimum flow requirements (2 feet (.6 m) per second in
discharge line), size pipe as follows:

Pipe Size (In/cm)

Flow Rate (GPM/LPH)

1-1/2 (3.8)

720/2700

2 (5.1)

1260/4740

2-1/2 (6.3)

1800/6780 

3 (7.6)

2880/10860

NOTICE:

Use Teflon™ tape on pipe connections.  Do not

use ordinary pipe joint compound on plastic pipe or
pump. Pipe joint compound can attack plastics and
damage pump.

3. To reduce motor noise and vibrations, a short length

of rubber hose (1-5/8"(41mm) I.D., e.g. radiator hose)
can be connected into discharge line near pump
using suitable clamps. 

4. If the pump discharge line is exposed to outside

subfreezing atmosphere, then the portion of line
exposed must be installed so any water remaining in
pipe will drain to outfall by gravity. Failure to do this
can cause water trapped in discharge to freeze which
could result in damage to pump.

5. Install a 2" check valve in the horizontal portion of

the discharge pipe. Make certain, the flow indicating
arrow, points away from the pump. This check valve
will keep the water from either running back into the
basin or into the area being pumped out when the
pump is not running. Check valve should be a free
flow valve that will easily pass solids.

NOTICE: 

For best performance of check valve when

handling solids, do not install it with discharge angled
more than 45° above the horizontal. Do not install check
valve in a vertical position as solids may settle in valve
and prevent opening on startup.

6. Drill a 3/16" (4.7mm) hole in discharge pipe about

1"-2" (2.5 - 5.1cm) above pump discharge

connection (but below check valve) to prevent
airlocking the pump.

7. Insert the float switch piggy-back plug into a

properly grounded outlet and the pump plug into the
piggy-back plug.

8. Check the installation by observing the pump

operation through one complete cycle. Make sure
that no parts of the assembly interfere with the float
switch.

Risk of flooding. May cause personal injury

or property damage. 

Failure to make this operational

check may lead to improper operation, premature failure,
and flooding.

Electrical

Hazardous voltage. Can shock, burn, or

cause death.

When installing, operating, or servicing this

pump, follow safety instructions listed below.

1. DO NOT splice the electrical power cord.

2. DO NOT allow electrical cord plug to be submerged.

3. DO NOT use extension cords. They are a fire hazard

and can reduce voltage sufficiently to prevent
pumping and/or damage motor.

4. DO NOT handle or service pump while it is

connected to power supply.

5. DO NOT remove grounding prong from plug or

modify plug.To protect against electrical shock, the
power cord is a three-wire conductor and includes a
3-prong grounded plug. Plug pump into a 3-wire,
grounded, grounding-type receptacle. Connect pump
according to electrical codes that apply.

For automatic operation, plug or wire pump into an
automatic float switch or pump controller. Pump will run
continuously when plugged directly into an electrical
outlet. Connect or wire pump to its own individual branch
circuit with no other outlets or equipment in the circuit.
Size fuses or circuit breakers according to chart on Page 2.

Risk of electrical shock and fire. Can burn or

cause death. 

Be sure that power supply information

(Voltage/Hertz/Phase) on pump motor nameplate matches
incoming power supply exactly. Install pump according to
all electrical codes that apply.

Operation

NOTICE:

Do not allow pump to run in a dry sump. It

will void the warranty and may damage the pump.
An automatic overload protector in the motor will
protect motor from burning out due to overheating/
overloading. When motor cools down, overload
protector will automatically reset and start motor.

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

TM

E.I. DuPont de Nemours and Company Corporation.

Summary of Contents for FPSE3500A

Page 1: ...2 English Pages 2 5 Installation Fonctionnement Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Français Pages 6 9 Instalación Operación Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 365 6832 Español Paginas 10 13 2010 FP829 7 9 10 FPSE3500A P O Box 342 Delavan WI 53115 Phone 1 800...

Page 2: ...nning can overheat pump causing burns to anyone handling it and will void warranty 7 Motors can operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling it 8 In normal service motor should not need oiling Motor has been filled at the factory with a special oil 9 The oil filled motor was not designed for use in water containing ...

Page 3: ...rge pipe about 1 2 2 5 5 1cm above pump discharge connection but below check valve to prevent airlocking the pump 7 Insert the float switch piggy back plug into a properly grounded outlet and the pump plug into the piggy back plug 8 Check the installation by observing the pump operation through one complete cycle Make sure that no parts of the assembly interfere with the float switch Risk of flood...

Page 4: ...ing 4 If overload trips frequently check for cause It could be a stuck impeller wrong low voltage or electrical failure in motor If an electrical failure in the motor is suspected have it serviced by a competent repairman Pump is permanently lubricated No oiling or greasing is required Service Hazardous voltage Can shock burn or cause death Before removing pump from basin for service always discon...

Page 5: ...del FP0S1775A Pool Cover Pump Model FP0S1790PCA Utility Pump Model FP0S4100X 2 Years Condensate Pump Model FPCP 20ULST Back up Sump Pump System Model FP2800DCC 4 Submersible Well Pumps 1 2 HP Submersible Sump Pumps 3 Years 1 3 HP Sump Pump Models FPSC2200A 10 and FPSC2250A 10 Pre Charge Water System Tank FP7100 Series 1 2 HP Sump Pump Models FPSC3200A 10 and FPSC3250A 10 5 Years Submersible Solids...

Page 6: ...ur éviter les brûlures lors des interventions sur la pompe la laisser refroidir après la mise à l arrêt pendant 20 minutes avant de la manipuler 8 Lors d une utilisation normale le moteur ne devrait pas avoir besoin d huile il a été lubrifié en usine avec une huile spéciale 9 Le moteur rempli d huile n est pas conçu pour être utilisé dans des eaux contenant des poissons Ne pas utiliser cette pompe...

Page 7: ...ntre 2 5 et 5 1 cm 1 et 2 po au dessus du raccord de refoulement de la pompe mais sous le clapet de non retour pour empêcher la formation de bouchons d air dans la pompe 7 Introduire la prise multiple de l interrupteur à flotteur dans une prise de courant adéquatement mise à la terre puis brancher la prise de la pompe dans la prise multiple de l interrupteur à flotteur 8 Vérifier l installation en...

Page 8: ...t de manipuler la pompe ou le moteur 2 Vérifier si la tension est bien présente 3 Vérifier si le niveau du liquide est suffisamment haut pour activer le contact ou la commande 4 Vérifier si le trou de ventilation de 4 7 mm 3 16èmes de pouce du tuyau d évacuation n est pas bouché 5 Vérifier un blocage de la crépine d entrée du rotor du clapet de non retour ou du tuyau d évacuation 6 Le disjoncteur ...

Page 9: ...0S4100X 2 ans Pompe de récupération des eaux condensées modèle FPCP 20ULST Système de pompage de secours de puisard de soutien modèle FP2800DCC Pompes de puits submersibles de 10 2 cm 4 po Pompes de puisard submersibles de 1 2 CV 3 ans Pompes de puisard submersibles de 1 3 CV modèles FPSC2200A 10 et FPSC2250A 10 Réservoir préchargé de système d eau gamme FP7100 Pompes de puisard submersibles de 1 ...

Page 10: ...l funcionamiento en seco sobrecalienta la bomba puede causar quemaduras a quien la manipule El sobrecalentamiento invalida la garantía 7 Los motores pueden funcionar a temperaturas altas Para evitar quemaduras al prestar servicios a la bomba déjela enfriar 20 minutos después de desconectarla y antes de manipularla 8 En servicio normal no es necesario aceitar el motor El motor ha sido lubricado en ...

Page 11: ...mba pero por debajo de la válvula de reten ción para evitar la creación de bolsas de aire en la bomba 7 Introduzca el enchufe superpuesto del interruptor de flotador en un tomacorriente debidamente puesto a tierra y el enchufe de la bomba en el enchufe superpuesto 8 Verifique la instalación observando el funcionamiento de la bomba a través de un ciclo completo Asegúrese de que ninguna pieza de la ...

Page 12: ...e servicio de su localidad 1 Si se levanta o sujeta la bomba por el cordón de alimentación eléctrica puede dañar el cordón y las conexiones 2 El cordón se puede salir dejando al descu bierto los alambres desnudos con la posi bilidad de incendio o choque eléctrico 3 Si levanta o sujeta la bomba por el cordón anulará la garantía 4 Use el anillo de elevación o la manija situada en la parte superior d...

Page 13: ...0F360AC Bombas de sumidero sumergibles INTELLIPUMP de 1 3 HP Modelo FP0S1775A Bomba para cubiertas de piscina Modelo F0S1790PCA 2 años Bomba para todo uso Modelo FP0S4100X Bomba de condensado Modelo FPCP 20ULST Sistema de bomba de sumidero de respaldo Modelo FP2800DCC Bombas de pozo sumerg bles de 4 Bombas de sumidero sumergibles de 1 2 HP 3 años Bombas de sumidero de 1 3 HP Modelos FPSC2200A 10 y...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ......

Reviews: