Flotec FPPSS5000 Owner'S Manual Download Page 4

Installation / Operation

4

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

INSTALLATION

1.

This unit can be installed in sump pit with min-
imum diameter of 12"(30cm) and depth of 12"
(30cm). Sump pit may be constructed of tile,
concrete, steel or plastic. Check local codes for
approved materials.

2.

Install pump on solid, level foundation, as near
as possible to center of sump pit. Do not hang
pump from discharge pipe or power cord.

NOTICE  

Pump must be level (column must be

vertical) when operating. If motor is tilted,
internal start/run switch may overheat and dam-
age motor.

3.

Pump should not be installed on clay, earth or
sand surfaces. Clean sump pit of small stones
and gravel which could clog the pump. Keep
pump inlet screen clear.

4.

Thread discharge pipe into pump body careful-
ly to avoid stripping or crossing threads.

NOTICE

Do not use ordinary pipe joint com-

pound on plastic pipe or pump. Pipe joint com-
pound can attack plastics and damage pump.

5.

To reduce motor noise and vibrations, a short
length of rubber hose (1-5/8"(41mm) I.D., e.g.
radiator hose) can be connected into discharge
line near pump using suitable clamps.

Risk of electric shock. 

Pump is

designed for 115V., 60 HZ

operation and requires an individual branch
circuit of 15 amperes capacity. It is supplied
with a 3-wire cord set with grounding-type
plug for use in a 3-wire, grounded outlet. Do
not cut off the round grounding prong. For safe-
ty, outlet must always be electrically grounded
to a suitable electrical ground such as a
grounded water pipe or a properly grounded
metallic raceway or ground wire system.

6.

Locate Float Rod Guide (Key No. 9) about 6"
(16cm) below motor. Clamp guide to column
with screw provided (Key No. 2).

Risk of flooding.

Be sure that

guide is securely clamped so

that float rod is vertical and can move up and
down freely. If float is angled or binds, pump
may not start, allowing flooding to occur.

7.

Screw float onto threaded end of rod. Threads
on rod will cut threads into corrosion resistant
float.

8.

Insert plain end of float rod up through eye of
rod guide.

9.

Slide one rod stop on float rod before passing
rod through eye of pump switch. Slide 2nd rod
stop on rod after passing through eye of switch.
Position 2nd rod stop flush with top of rod.

10. Position lower rod stop to within 8"(20cm) of

switch lever arm. With lower rod stop in this
position, pump will automatically cycle at
approximately 2-1/2"(6cm) off and 10-12"(25-
30cm) on. For faster cycling, move lower rod
stop closer to switch lever arm.

11. If pump discharge line is exposed to outside

subfreezing atmosphere, then portion of line
exposed must be installed so any water remain-
ing in pipe will drain to outfall by gravity.
Failure to do this can cause water trapped in
discharge to freeze which could result in dam-
age to pump.

12. Install an in-line check valve (Flotec No.

FP0026-6D) to prevent flow backwards through
pump after pump shuts off.

NOTICE

Flotec check valves are equipped with

an air bleed hole to prevent airlocking the
pump. If using a check valve that is not a Flotec
valve, drill a 1/8" (3.2mm) hole in discharge
pipe just above pump body but below the
check valve to prevent air locks.

13. After all piping and controls have been

installed, unit is ready for operation.

14. Run pump through one cycle to check float

switch operation.

Unexpected Starts. 

The pump

motor is equipped with auto-

matic resetting thermal protector and may
restart unexpectedly. Protector tripping is an
indication of motor overloading as a result of
operating pump at low heads (low discharge
restriction), excessively high or low voltage,
inadequate wiring, incorrect motor connec-
tions, or a defective motor.

OPERATION

Risk of Burns. 

Do not touch sump

pump, pump motor, water, or dis-

charge piping when pump is connected to electrical
power. Always disconnect pump cord (power)
before handling.
1.

Plug this unit into a 115V outlet, on an individ-
ual branch circuit, with a Class A, 15 amp
GFCI (Ground Fault Circuit Interrupter).
Consult your local electrician for information 
and availability.

2.

Fill sump pit with water, pump will start auto-
matically when lower rod stop actuates switch
lever arm. When upper rod stop actuates switch
lever arm, pump will stop.

NOTICE

Do not allow pump to run dry.

Risk of Shock. 

Before attempt-

ing to service, always discon-

nect power from unit.

3.

The motor is equipped with an automatic reset
thermal protector to protect unit from overheat-
ing. When motor has cooled sufficiently, switch
will reset automatically and restart motor.
Repeated tripping could be caused by low volt-
age, long extension cords, clogged impeller,
very low head or lift, etc. Cycling of protector
will cause eventual motor burnout.

Summary of Contents for FPPSS5000

Page 1: ...s For further operating installation or maintenance assistance Call 1 800 365 6832 English Pages 2 6 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installat...

Page 2: ...tore Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pum...

Page 3: ...n condition before each use making certain all connections are secure 7 Inspect sump pump and system components monthly Keep free of debris and foreign objects Perform routine maintenance as required...

Page 4: ...h with top of rod 10 Position lower rod stop to within 8 20cm of switch lever arm With lower rod stop in this position pump will automatically cycle at approximately 2 1 2 6cm off and 10 12 25 30cm on...

Page 5: ...ctrical malfunction Check power cord automatic switch and motor Replace faulty parts as needed Motor runs but Inlet clogged Check inlet and clean if needed pump will not Discharge line plugged Clear d...

Page 6: ...h 1 2 Set Screw 4 U30 946PH 3 Shaft 1 RP0005257 4 Support Column 1 S15 37SS 5 Volute 1 S1 34B 6 Impeller 1 S5 13P 7 Base Plate 1 PS4 17P 8 Screw base plate 8 U30 571BT 9 Float Rod Guide 1 RP0005249 10...

Page 7: ...s pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe de...

Page 8: ...se d place pas dans le puisard 5 Caler la canalisation de refoulement avant de d marrer la pompe Une canalisation non cal e peut donner des coups de fouet qui risquent de provoquer des blessures corpo...

Page 9: ...orsque le dispositif d arr t inf rieur se trouve dans cette position le cycle de la pompe se r gle automatiquement 6 cm 2 1 2 po pour l arr t et 25 cm 10 12 po pour la marche Pour un cycle plus rapide...

Page 10: ...ique interrupteur automatique lectrique et moteur Remplacer les pi ces d fectueuses si n cessaire Le moteur Cr pine bouch e V rifier la cr pine et la nettoyer si n cessaire tourne mais Canalisation de...

Page 11: ...base 1 PS4 17P 8 Vis plaque de base 8 U30 571BT 9 Guide de tige du flotteur 1 RP0005249 10 Vis colonne volute non repr sent e 1 U30 946PH 11 Flotteur 1 FT0013 63 12 Tige du flotteur 1 RP005168S 13 Dis...

Page 12: ...tamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado Use guantes...

Page 13: ...descarga est suelta puede latiguear ocasionando posibles da os personales y o materiales 6 Inspeccione las mangueras antes de usar la bom ba para asegurarse de que est n en buen estado y verifique que...

Page 14: ...pe inferior de la varilla a unas 8 20 cm del brazo de la palanca del interruptor Con el tope inferior de la varilla en esta posici n la bomba tendr ciclos autom ticos de aproximadamente 2 1 2 6 cm afu...

Page 15: ...ico y el motor Reemplace las partes defectuosas seg n sea necesario El motor Entrada tapada Inspeccione la entrada y l mpiela si fuera necesario funciona pero Tuber a de descarga Limpie la tuber a de...

Page 16: ...4 Columna de Soporte 1 S15 37SS 5 Espiral Caja de la Bomba 1 S1 34B 6 Impulsor 1 S5 13P 7 Placa de asiento 1 PS4 17P 8 Tornillo placa de asiento 8 U30 571BT 9 Gu a de la Varilla del Flotador 1 RP00052...