Flotec FP5100 Owner'S Manual Download Page 2

Safety

2

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. 

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury:

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

can

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.

The label 

NOTICE

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 

Replace missing or damaged safety labels.

Make workshops childproof; use padlocks and master
switches; remove starter keys.

ELECTRICAL SAFETY

Capacitor voltage may be hazardous.

To

discharge motor capacitor, hold insulated handle screw-
driver 

BY THE HANDLE

and short capacitor terminals

together. Do not touch metal screwdriver blade or
capacitor terminals. If in doubt, consult a qualified 
electrician. 

GENERAL SAFETY

Do not touch an operating motor.

Modern

motors are designed to operate at high temperatures. To
avoid burns when servicing pump, allow it to cool for 20
minutes after shut-down before handling.

Pump is designed as a lawn sprinkler only. To avoid heat
built-up, over pressure hazard and possible injury, do not
use in a domestic water system. Do not use as a booster
pump; pressurized suction may cause pump body to
explode.

Do not allow pump or any system component to freeze.
To do so will void warranty.

Pump water only with this pump.

Periodically inspect pump and system components.

Wear safety glasses at all times when working on pumps.

Keep work area clean, uncluttered and properly lighted;
store properly all unused tools and equipment.

Keep visitors at a safe distance from the work areas.

“Dead Heading” a pump means running the pump
while little or no water is released from the system.

Never 

run pump above recommended pressure shown

on the performance chart.

WARNING

Hazardous pressure! 
Do not run pump against
closed discharge.

Release all pressure on 
system before working on 
any component.

WARNING

Hazardous voltage.
Can shock, burn, or
cause death.

Ground pump before 
connecting to power 
supply. Disconnect power
before working on pump,
motor or tank.

Wire motor for correct

voltage. See “Electrical”

section of this manual and
motor nameplate.

Ground motor before

connecting to power 

supply.

Meet National Electri-

cal Code, Canadian

Electrical Code, and local
codes for all wiring.

Follow wiring instruc-

tions in this manual

when connecting motor to
power lines.

Summary of Contents for FP5100

Page 1: ...365 6832 English Pages 2 11 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 12 21 Instal...

Page 2: ...perate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Pump is designed as a lawn sprinkler only To avoid heat built up over pre...

Page 3: ...or purchasing a top quality factory tested pump Page General Safety 2 Installation 4 5 Electrical 6 7 Operation 8 Troubleshooting 9 Repair Parts 10 Warranty 11 For parts or assistance call Flotec Cust...

Page 4: ...atic internal cutoff switch Before handling pump or motor stop motor and allow it to cool for 20 minutes WELL PIPE INSTALLATION NOTICE Use installation method below which matches your well type CASED...

Page 5: ...ipe Do not use hose or plastic tubing See Well Pipe Installation for more information NOTICE Use only Teflon tape or Teflon based joint compounds for making all threaded connections to the pump itself...

Page 6: ...cover 2 metal tabs The arrow on the plug will point to 115V 4 Attach the power lead wires to the power lead termi nals Make sure the wires are secure 5 Attach the ground wire to the green ground screw...

Page 7: ...10 feet long Do not connect to plastic pipe or insulated fittings Step 6 Protect current carrying and grounding conduc tors from cuts grease heat oil and chemicals Step 7 Connect current carrying cond...

Page 8: ...water not more than 20 6 m and length of horizon tal run 10 3 m of horizontal suction pipe 1 30 5 cm of vertical lift due to friction losses in pipe If no water is produced within 10 minutes stop pum...

Page 9: ...lost prime through In installation already in use 1 Air leaks 1 Check all connections on suction line and shaft seal with soapy water 2 Water level below suction pipe inlet 2 Lower suction line into...

Page 10: ...late Complete L176 47P1 L176 47P1 C103 189P 11 V Clamp C19 54SS C19 54SS C19 37A 12 Pump Body Front Half C176 53P C176 53P C176 62P 14 Base C4 42P C4 42P C4 42P Seal and Gasket Kit FPP5000 FPP5000 FPP...

Page 11: ...n nor due to improper installation operation mainte nance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or o...

Page 12: ...la pompe la laisser refroidir pen dant 20 minutes apr s l avoir arr t e avant de la toucher La pompe est con ue uniquement en tant que syst me d arrosage gazon Pour viter toute accumulation de chaleur...

Page 13: ...lient le Flotec en composant le 1 800 365 6832 Table des mati res 13 Merci d avoir achet une pompe de qualit sup rieure mise l essai l usine Page S curit 12 Installation 14 15 lectricit 16 17 Fonction...

Page 14: ...enchement automatique Avant de manipuler la pompe ou le moteur arr ter le moteur et le laisser refroidir pendant 20 minutes INSTALLATION DE LA TUYAUTERIE DU PUITS REMARQUE Appliquer la m thode d insta...

Page 15: ...installation et le bon fonction nement appeler le service la client le Utiliser un tuyau rigide Ne pas utiliser de tuyaux flexibles ou en plastique Voir Installation de la tuyauterie du puits pour pl...

Page 16: ...es fils d alimentation sur les bornes S assurer que les fils sont bien retenus en place 5 Brancher le fil de mise la terre sur la vis verte de mise la terre 6 Reposer le couvercle du moteur Passer la...

Page 17: ...sur le tubage d un puits ayant au moins 10 pieds de long Ne pas brancher sur un tuyau en plastique ou sur des raccords isol s 6 Prot ger les conducteurs transporteurs de courant mis la terre contre le...

Page 18: ...m 20 pi et de la longueur de canalisation horizontale 3 m 10 pi de tuyau d aspiration horizontal 30 5 cm 1 pi d l vation verticale provoqu e par les pertes de friction dans le tuyau Si la pompe n extr...

Page 19: ...pompe pompe Si la baisse de niveau de l eau dans le puits est sup rieure la force d l vation de l aspiration il faut utiliser une pompe de puisage en eau profonde La roue motrice est bloqu e Nettoyer...

Page 20: ...KG 4 Plaque d tanch it L176 47P1 L176 47P1 C103 189P 11 Collier C19 54SS C19 54SS C19 37A 12 Molti avant du corps de la pompe C176 53P C176 53P C176 62P 14 Socle C4 42P C4 42P C4 42P N cessaire de bag...

Page 21: ...s correctement ni ceux qui n ont pas t utilis s ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pan nes de fonctionnement caus es par la corrosion la rouille ou autre...

Page 22: ...pu s de apagarla Esta bomba se ha dise ado para ser usada nicamente en rociadores de c sped Para evitar peligros de recalen tamiento o sobrepresi n y posibles lesiones no la use en un sistema de agua...

Page 23: ...ente al 1 800 365 6832 Indice de Contenido 23 Gracias por adquirir una bomba de calidad superior que ya ha sido probada en la f brica Page Seguridad General 22 Instalaci n 24 25 Electricidad 26 27 Ope...

Page 24: ...damente 20 minutos INSTALACI N DEL TUBO EN EL POZO AVISO Use el m todo de instalaci n descrito a continuaci n que mejor se adapte al tipo de pozo que usted tiene INSTALACI N EN POZO REVESTIDO O EN POZ...

Page 25: ...e Use tuber a rigida No utilice mangueras o tubos de pl stico Para mayor informaci n cons ltese la secci n Instalaci n de la tuber a en el pozo AVISO Utilice solamente cinta de tefl n o compuestos par...

Page 26: ...cte el cable de puesta a tierra al tornillo verde de pues ta tierra 6 Vuelva a colocar la cubierta del motor Pase a la secci n de Conexiones de Cableado a continuaci n SELECTOR DE TENSI N TIPO CUADRAN...

Page 27: ...nea o una envoltura para pozos de por lo menos 10 pies de largo No conecte a un tubo de pl stico o a accesorios aislados Paso 6 Proteja los conductores de puesta a tierra y los que lle van la corrient...

Page 28: ...a bomba del agua que no debe ser mayor de 20 pies 6 m y de la longitud del tramo horizontal 10 pies o 3 m de tubo horizontal de suc ci n que equivalen a 1 pie 30 5 cm de ascenso verti cal debido a las...

Page 29: ...tuber a usando el tama o de los orificios de aspiraci n y descarga en la bomba La bomba ha perdido el cebado debido a En instalaciones ya en uso 1 Fugas de aire 1 Verifique las conexiones en la l nea...

Page 30: ...J218 883APKG 4 Placa Obturadora Completa L176 47P1 L176 47P1 C103 189P 11 Abrazadera C19 54SS C19 54SS C19 37A 12 Mitad Delantera del Cuerpo de la Bomba C176 53P C176 53P C176 62P 14 Base C4 42P C4 42...

Page 31: ...eraciones ni debido a instalaci n funcionamiento mantenimiento o almacenaje incorrectos ni a ningu na otra cosa que no sea su aplicaci n uso o servicio normales incluyendo pero no limitado a fallas op...

Page 32: ......

Reviews: