Flotec FP0S1700A Series Operation & Installation Instructions Download Page 2

FLOTEC LIMITED WARRANTY

FLOTEC warrants to the original consumer purchaser (“Purchaser”) of its products that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth
below. Your original receipt of purchase is required to determine warranty eligibility.

Exceptions to the Twelve (12) Month Warranty

Ninety (90) Day Warranty:

If within ninety (90) days from original consumer purchase any Drill Pump, Pitcher Pump, or In-Line Water Filter Cartridge shall prove to be defective, it shall be replaced, subject to the terms set forth below.

Two (2) Year Warranty:

If within two (2) years from original consumer purchase any 1/3 HP Submersible Sump Pump or Model FP2800DCC shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and con-
ditions set forth below.

Three (3) Year Warranty:

If within three (3) years from original consumer purchase any 4” Submersible Well Pump, or 1/2 HP Submersible Sump Pump, shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the
terms and conditions set forth below.

Four (4) Year Warranty:

If within four (4) years from original consumer purchase any FLOODMATE

TM

7000 or IRONMATE

TM

Submersible Sump Pump shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms

and conditions set forth below.

Five (5) Year Warranty:

If within five (5) years from original consumer purchase any Pre-Charge water system tank shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below.

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to acts of God, nor shall it apply to products which, in the sole judgement of FLOTEC,
have been subject to negligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation, maintenance or storage; nor to other than normal application, use or service, including but
not limited to, operational failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to FLOTEC as soon as possible after the discovery of any alleged defect. FLOTEC will subsequently take correc-
tive action as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty.
This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty
gives you specific legal rights and you may also have other rights which vary from state to state.

FLOTEC • P.O. Box 342 • Delavan, WI U.S.A. 53115

Phone: 1-800-365-6832 • Fax: 1-800-526-3757 • E-Mail: [email protected] • Web Site: http://www.flotecwater.com

SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t start or run.

Blown fuse.

If blown, replace with fuse of proper size.

Low line voltage.

If voltage under recommended minimum, check size of wiring from
main switch on property. If OK, contact power company or hydro
authority.

Defective motor.

Replace pump.

Defective float switch.

Replace pump.

Impeller.

If impeller won’t turn, locate source of binding and clean out with
hose or remove.

Float obstructed.

Remove obstruction.

Pump starts and stops

Backflow of water from piping.

Install or replace check-valve.

too often.

Faulty float switch.

Replace pump.

Pump won’t shut off.

Defective float switch.

Replace pump.

Restricted discharge 

Remove pump and clean pump and piping.

(obstacle in piping).
Float obstructed.

Remove obstruction.

Pump operates but

Low line voltage.

If voltage under recommended minimum, check size of wiring from main

delivers little or no water.

switch on property. If OK, contact power company or hydro authority.

Something caught in impeller.

Clean out impeller or replace pump.

Worn or defective parts or

Clean impeller if plugged; otherwise replace pump.

plugged impeller.
Check valve installed without

Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump 

vent hole.

discharge & check valve.

TROUBLESHOOTING CHART

2

OPERATION

Risk of electric shock. Do not handle a pump or pump
motor with wet hands or when standing on wet or damp

surface, or in water.

1. Shaft seal depends on water for lubrication. Do not operate pump unless it

is submerged in water as seal may be damaged if allowed to run dry.

2. Motor is equipped with automatic reset thermal protector. If temperature in

motor should rise unduly, switch will cut off all power before damage can
be done to motor. When motor has cooled sufficiently, switch will reset
automatically and restart motor. If protector trips repeatedly, pump should
be removed and checked as to cause of difficulty. Low voltage, long exten-
sion cords, clogged impeller, very low head or lift, etc., could cause cycling.

3. Pump will not remove all water. If manually operated pump is operating

and suddenly no water comes out discharge hose, shut off unit immediate-
ly. Water level is probably very low and unit has broken prime.

NOTICE: 

For continuous operation, water depth must be at least 5"

(127mm) to prevent motor overheating.

Risk of electric shock. Before attempting to check
why unit has stopped operating, discon-

nect power from unit. Do not handle pump with wet hands or 
when standing on wet or damp surfaces, or in water.

5"

(127mm)

3127 1297

Float Switch Tether Length:

NOTICE:

Do not change tether length of float switch. Float must swing through its

complete arc without interference.

NOTICE:

This pump has no serviceable parts inside case. Opening case will ruin pump. If obstructions or blockages of impeller cannot be

cleaned out from the outside (for instance, by washing out with a garden hose), replace pump.

Hazardous voltage; can shock, burn or kill.

Unplug pump before attempting to clean or work on pump.

Summary of Contents for FP0S1700A Series

Page 1: ...pump in a fish pond If your basement has water or moisture on floor do not walk on wet area until all power has been turned off If shut off box is in basement call electric company or hydro authority...

Page 2: ...ABLE EXPRESS WARRANTIES PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above li...

Page 3: ...utiles c Les visiteurs doivent se tenir une distance s curitaire de la zone de travail d Poser des cadenas pour s assurer que les enfants ne pour ront pas p n trer dans l atelier de travail Poser auss...

Page 4: ...u d eau mis la terre une canalisation m tallique ad quatement mise la terre ou un circuit lectrique ad quatement mis la terre par exemple Ne jamais couper la broche ronde de mise la terre de la fiche...

Page 5: ...dessous Garantie de quatre 4 ans Si dans les quatre 4 ans compter de la date d achat par le consommateur d origine une pompe d ass chement submersible FLOODMATEMD 7000 ou IRONMATEMD s av rait tre d fe...

Page 6: ...se use c Mantenga a los visitantes a una distancia segura del lugar de trabajo d Aseg rese de que su taller sea a prueba de ni os con candados interruptores maestros y sacando las llaves del arrancado...

Page 7: ...st puesta a tierra o un conducto met lico debidamente puesto a tierra o un sistema de alambre de puesta a tierra No corte la clavija redonda de puesta a tierra 8 Si la tuber a de descarga de la bomba...

Page 8: ...osible Ning n pedido de servicio bajo esta garant a ser aceptado si se recibe m s de 30 d as despu s del t rmino de la garant a Esta garant a establece la obligaci n nica de FLOTEC y el remedio exclus...

Reviews: