If foreign bodies are present, block-
ing hydraulics => clean the hydraulic
components
•
Thermal cutout protection setting or
fuses not suitable => check protection
devices with respect to rated current
of pump
•
Power cable damaged => replace
component
•
Motor damaged => replace component
•
Electronic control device has started
: error message => " DRY RUN-
NING" and blinking red led RUN/
FAULT:
1.
the pump is not primed: please
repeat all priming operations.
2.
the pump sucks air : please
check the liquid level, the check
valve conditions and the conditions
of the suction pipe.
3.
the check valve is obstructed:
please clean it or change it
SET
ESC
MODE
LINE
RUN
FAULT
DRY
RUNNING
•
The electronic device tries 4 times to
start up automatically before giving
alarm signal. After the falut signal
the pump restarts after 1, 5, 60, 720
minutes. By pressing on button ESC
it is possible to manually reset the
fault.
SET
ESC
MODE
LINE
RUN
FAULT
4.3 BAR
PRESSURE
•
The electronic control device has
started: error message = "FAULT
SENSOR" and there is a blinking red
led RUN/FAULT : the control device
cannot interact with the pressure
sensor. Please check the sensor
connection to the device and call the
service center.
SET
ESC
MODE
LINE
RUN
FAULT
FAULT
SENSOR
!
•
The electronic control device has
started; the fault message shown on
the display is = "ELECTRIC FLT" and
there is a blinking red led RUN/FAULT