Safety   

2

 

Important Safety Instructions

 

SAVE THESE INSTRUCTIONS - This manual contains 

important instructions that should be followed during 
installation, operation, and maintenance of the product. 

 

 This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of the 
following signal words and be alert to the potential for 
personal injury!

 

indicates a hazard which, if not avoided, 

 

will

 result in death or serious injury. indicates a hazard 

which, if not avoided, 

 

can

 result in death or serious injury. indicates a hazard 

which, if not avoided, 

 

can 

or

 may

 result in minor or moderate injury. 

NOTICE

 

addresses practices not related to personal injury. 

Carefully 

read and follow all safety instructions in this manual and 
on pump.

 

Keep safety labels in good condition. Replace missing or 

damaged safety labels.

 

To avoid risk of serious bodily injury due to electrical shock 

or burns and property damage due to flooding, read the 
safety instructions carefully before installing pump.

 

 Battery acid is corrosive. Do not spill on skin, 

clothing, or battery charger.

 Wear eye and head protection 

when working with battery. Connect and disconnect DC 
output terminals only after removing the charger from the 
AC outlet. Never allow the DC terminals to touch each other. 

 

 Hazardous Voltage. Can cause severe or fatal 

electrical shock.

 Do not plug in or unplug battery charger 

while standing on a wet floor or in water. Be sure one hand 
is free when plugging in or unplugging charger. If basement 
floor is wet, disconnect power to basement before walking 
on floor. 

 

Risk of flooding. Do not run pump dry.

 To do 

so will damage seals and can cause leaking 

and property damage. 

 

Follow local and/or national plumbing and electrical codes 

when installing the system. A ground fault circuit 
interrupter (GFCI) is recommended for use on any 
electrical appliance submerged in water. Use this system 
only for backup sump pump duty in a residential 
application. It is not designed as a primary sump pump.

 

Do not lift pump by electrical cord.

 

 Risk of electrical shock.

 Do not lift the pump 

by the electrical cord; lift pump only by the discharge pipe, 
lifting ring or handle on the pump. Lifting by the cord can 
damage the cord.

 

Pump clear water only with this pump.

 

Pump is permanently lubricated at the factory. Do not try to 

lubricate it!

 

Keep battery charger and battery box off of the floor and in 

a dry, cool, well ventilated area.

 

NOTICE:

 If a Carbon Monoxide (CO) sensor is installed, it 

must be at least 15 feet away from battery charger in order 
to avoid nuisance CO alarms. Please refer to your CO 

detector’s installation guidelines for more information.

 

To avoid danger of fire or explosion, keep sparks and flame 

(pilot light) away from battery.

 

Maximum vertical pumping distance is 14 feet (4.3M) for 

Model FPDC20.

 

Make sure sump is clear of debris. Debris can damage the 

pump which can result in flooding.

 

GENERAL INFORMATION

 

The battery backup sump system is not a substitute for your 

primary sump pump. It is designed to temporarily backup 
your primary sump pump during a power outage or other 
problem which prevents normal operation of the primary 
pump. Do not use this system to pump flammable liquids or 
chemicals. Pump clear water only with this pump.

 

Keep the battery charger dry and protected from damage.

 

This system is designed to work with a deep cycle sealed 

maintenance free lead-acid AGM battery. It will also work 
with a flooded lead acid battery. Gell and Sealed flooded 
lead acid batteries are 

not

 

recommended

. In an emergency 

(such as an extended power outage) which depletes the 
system deep cycle battery, your automobile battery may be 
temporarily substituted. Be sure to replace the system deep 
cycle battery as soon as possible. Use of an automobile 
battery instead of a deep cycle battery in this system will 

significantly reduce the system’s total performance. 

Automobile batteries are not designed for this type of 
application and will be quickly ruined by the repeated 
charge/discharge cycling. 

NOTICE: 

This system is not 

designed for applications involving salt water, brine, or 
where fish may be present! Use with these will void 
warranty. 

 

California Proposition 65 Warning

 

 This product and related accessories contain 

chemicals known to the State of California to cause cancer, 
birth defects or other reproductive harm.

 

BASIC TOOLS AND PARTS NEEDED  
(Purchase Separately) 

Channel locks or large adjustable pliers

 

Tape measure

 

Socket wrench or 5/16” nut driver

 

Side cutters

 

Hacksaw (to cut PVC pipe)

 

Medium size pliers

 

Slotted screwdriver

 

 

 

 

 

Installation  

3

 

Summary of Contents for BDWWHU

Page 1: ...OWNER S MANUAL BDWWHU Backup System...

Page 2: ...fting by the cord can damage the cord Pump clear water only with this pump Pump is permanently lubricated at the factory Do not try to lubricate it Keep battery charger and battery box off of the floo...

Page 3: ...rectly outdoors separate discharge pipe from the primary sump pump discharge pipe If this is not a practical option see the Common Discharge Figure 3 Page 4 option NOTICE For ALL installations once th...

Page 4: ...tallation if the Primary Sump Pump PSP does not have a check valve installed below the wye you MUST install a check valve for the PSP as shown This prevents backflow of water into the sump from the Ba...

Page 5: ...charge pipes Figure 3 Typical installation with common discharge pipe INSTALLATION Typical Separate Discharge Risk of electrical shock Can shock burn or kill Unplug the primary sump pump before beginn...

Page 6: ...Leave the hose clamps loose and slide the Assembly down below the top of the riser pipe 9 Determine where you want the discharge to exit the basement At that point drill the necessary holes large enou...

Page 7: ...he discharge pipe install one now 9 Cut a length of discharge pipe for the PSP to fit between the check valve and a 45 slip wye Be sure to allow for the overlap needed for gluing joints 10 Install the...

Page 8: ...case from chipping and gouging do not let the battery sit on a concrete floor Install the battery on a shelf or protective pad plywood 2x4s etc Always install the battery in a dry location that is pro...

Page 9: ...ions for maintenance and safe use of the battery 1 Connect the positive charger controller lead wire red to the positive battery terminal red Connect the negative charger controller lead wire black to...

Page 10: ...e SILENCE ALARM button again for one second Depress the SYSTEM TEST button hold it for one second release The PUMP STATUS LED should stop flashing Wiring Setup NOTICE During normal operation the flash...

Page 11: ...when it first receives power from the battery the BATTERY STATUS LED will flash for 3 seconds NOTICE To activate any Control Button press and hold it for 1 second LED Display TABLE II Operating Code...

Page 12: ...he LED Charging Indicates that the battery is charging see Table II above Battery Status A Continuous ON the battery voltage is above 10 9 Volts DC and capacity is above 20 B Slow Beep Slow LED Flash...

Page 13: ...S LED When pushed with the SILENCE ALARM button the Charger Controller microprocessor resets and error code resets Silence Alarm Toggle Prevents the audible alarm sounding Press and release to reset L...

Page 14: ...primary pump discharge and the Battery Backup wye Check for an obstruction in the discharge pipe The discharge pipe length and or height exceeds the capacity of the pump See Table VI Page 11 for pump...

Page 15: ...012 3 Float Switch PS17 2003 4 Charger Controller PS217 1521 5 Battery Case Complete PS17 1512 6 AC Adaptor PS17 2008 7 11 x 14 Plastic Cable Tie Purchase separately If pump fails replace entire syste...

Page 16: ......

Page 17: ...15...

Reviews: