background image

13

 

LED Display  

 

 

TABLE V 

 Control Button Functions

 

Control Button:

 

Result of Pushing Button:

 

System Test

 

Pump starts and all LEDs light up.

 

Will reset the ‘PUMP STATUS’ LED.

 

When pushed with the ‘SILENCE ALARM’ button, the Charger/Controller microprocessor resets and 

error code resets.

 

Silence Alarm 

 

Toggle; Prevents the audible alarm sounding. Press and release to reset. 

 

Light

 

Toggles the flood light on the Charger/Controller on and off.

 

System Reset

 

Press and release ‘SYSTEM TEST’ and ‘SILENCE ALARM’ to reset system.

 

Troubleshooting  

 

Summary of Contents for BDWWHU

Page 1: ...OWNER S MANUAL BDWWHU Backup System...

Page 2: ...fting by the cord can damage the cord Pump clear water only with this pump Pump is permanently lubricated at the factory Do not try to lubricate it Keep battery charger and battery box off of the floo...

Page 3: ...rectly outdoors separate discharge pipe from the primary sump pump discharge pipe If this is not a practical option see the Common Discharge Figure 3 Page 4 option NOTICE For ALL installations once th...

Page 4: ...tallation if the Primary Sump Pump PSP does not have a check valve installed below the wye you MUST install a check valve for the PSP as shown This prevents backflow of water into the sump from the Ba...

Page 5: ...charge pipes Figure 3 Typical installation with common discharge pipe INSTALLATION Typical Separate Discharge Risk of electrical shock Can shock burn or kill Unplug the primary sump pump before beginn...

Page 6: ...Leave the hose clamps loose and slide the Assembly down below the top of the riser pipe 9 Determine where you want the discharge to exit the basement At that point drill the necessary holes large enou...

Page 7: ...he discharge pipe install one now 9 Cut a length of discharge pipe for the PSP to fit between the check valve and a 45 slip wye Be sure to allow for the overlap needed for gluing joints 10 Install the...

Page 8: ...case from chipping and gouging do not let the battery sit on a concrete floor Install the battery on a shelf or protective pad plywood 2x4s etc Always install the battery in a dry location that is pro...

Page 9: ...ions for maintenance and safe use of the battery 1 Connect the positive charger controller lead wire red to the positive battery terminal red Connect the negative charger controller lead wire black to...

Page 10: ...e SILENCE ALARM button again for one second Depress the SYSTEM TEST button hold it for one second release The PUMP STATUS LED should stop flashing Wiring Setup NOTICE During normal operation the flash...

Page 11: ...when it first receives power from the battery the BATTERY STATUS LED will flash for 3 seconds NOTICE To activate any Control Button press and hold it for 1 second LED Display TABLE II Operating Code...

Page 12: ...he LED Charging Indicates that the battery is charging see Table II above Battery Status A Continuous ON the battery voltage is above 10 9 Volts DC and capacity is above 20 B Slow Beep Slow LED Flash...

Page 13: ...S LED When pushed with the SILENCE ALARM button the Charger Controller microprocessor resets and error code resets Silence Alarm Toggle Prevents the audible alarm sounding Press and release to reset L...

Page 14: ...primary pump discharge and the Battery Backup wye Check for an obstruction in the discharge pipe The discharge pipe length and or height exceeds the capacity of the pump See Table VI Page 11 for pump...

Page 15: ...012 3 Float Switch PS17 2003 4 Charger Controller PS217 1521 5 Battery Case Complete PS17 1512 6 AC Adaptor PS17 2008 7 11 x 14 Plastic Cable Tie Purchase separately If pump fails replace entire syste...

Page 16: ......

Page 17: ...15...

Reviews: