Port Type - Input Program
Function
This screen is used to program an input (or output) port for the installed port module. The input Port
Type may be programmed to service the selected input signal Type and Execution.
Navigation
Access this screen by using the CHAN key until reaching the desired port number, and then by using
the PROG key until reaching this screen. Note the display Type field portion blinks indicating
readiness for programming.
Select
Field - independently select the input signal field or excitation field using the QTY (right) or
CHAN (left) keys.
Type Field - select an input signal type by pressing either the ZERO (down) or RATE (up) key
to select one of the following:
o
Freq
(0-24,570Hz)
o
Volt
(0-4000mV)
o
Volt
(0-10V)
o
Current
(0-20mA)
o
Ohms
Excitation Field - select Excitation by pressing either the ZERO (down) or RATE (up) key to
select from the following:
o
+5.0
volts
o
+12 volts
o
Vn volts
Program - save new Type and Excitation selections by pressing the PROG key.