Pump
Unit
24Vdc
Motor
Connect
to
Solvent
Fl h
Bulk
Filter
5um
Luer
Connecto
purged out through all nozzles. In this operation, the nozzles are being cleaned from slight
contamination of small debris, and micro-bubbles will be forced out.
Maintenance Toggle Button
Solvent Flush Toggle Switch
– used for flushing the solvent into
the Print head. This is being done if you want to remove the ink
out of the Print head or to remove any clogging from the Print
head.
Media Suction Switch
– vacuum switch to make sure that the
media is laid down flat on the printing platform.
Negative Pressure Adjustment
– used to adjust the Negative
Pressure value as being shown in the Pressure Gauge
4.6 Flushing System
This system provides solvent flushing for all print heads. A solvent
pump is provided to pump the solvent from the solvent bottle to ink tank
manifold then it is distributed through the ink tank manifold. The manifold
valve can be turned individually to appropriately enable the flow of solvent
flush to each particular print head. The solvent pump is turn-on/activated by
a toggle switch that provides the 24Vdc to the solvent pump unit.
The solvent flushing can be done to all print heads at the same time or
only print head at one time by closing and opening the ink tank valves
accordingly. Solvent flush is necessary if there is stubborn clogging in the
print head nozzles or when the machine will not operate over night
Notice: If had to replace the ink , all ink line must be flush to clear!.
Fig. 4.6-1:
Solvent Pump
Ink
Tank
Flush
LCF Disc
Filter
(5um.)
Solvent
Flush
Bottle
M
High Level
Low Level
Solvent
Pump
Level Sensor
(Optional)
Bulk Ink Filter
(5um.)
Magnetic
Floater
Ink
inlet
Negative
Pressure
24Vdc
Motor
Head
Manifold
Valve
Flushing
Switch
+24Vdc
Fig. 4.6-2: Flush Circuit
Fig. 4.5.6-1: Maintenance Panel