Power system
External power operation
AC adapter 90–260 VAC, 50/60 Hz or 12 V from a
vehicle (cable with standard plug, optional)
DC operation
8 to 15.3 V DC, polarity protected (proprietary
protected)
Power
8.5 W typically
Start-up time
Typically 7 min. @ 25°C (+77°F)
Environmental data
Operating temperature range
–20°C to +50°C (–4°F to +122°F)
Ambient temperature range (certification range for
explosive atmospheres)
–20°C to +40°C (–4°F to +104°F)
Storage temperature range
–30°C to +60°C (–22°F to +140°F)
Humidity (operating and storage)
IEC 68-2-30/24 h 95% relative hu25°C to
+40°C (+77°F to +104°F) (2 cycles)
Explosive (hazardous) environment
•
IEC 60079-0:2011
•
IEC 60079-11:2011
•
IEC 60079-15:2010 (partial)
•
IEC 60079-28:2015
•
BS EN 60079-0:2012
•
BS EN 60079-11:2012
•
BS EN 60079-15:2010
•
BS EN 60079-28:2015
•
ANSI/ISA-12.12.01-2013
•
CSA 22.2 No. 213
•
ATEX directive 2014/34/EU
Low voltage
73/23/EEC
RoHS
2011/65/EU
WEEE
2012/19/EU
EMC
•
The Electromagnetic Compatibility (EMC) Di-
rective 2014/30/EU
•
EN61000-6-4 (Emission)
•
EN61000-6-2 (Immunity)
•
FCC 47 CFR Part 15 class A (Emission)
•
EN 61 000-4-8, L5
Encapsulation
IP 54 (IEC 60529)
Shock
25 g (IEC 60068-2-27)
Vibration
2 g (IEC 60068-2-6)
Safety
EN/UL/IEC 60950-1
Physical data
Camera weight, incl. battery
2.80 kg (6.18 lbs.)
Camera weight, excl. battery
2.59 kg (5.71 lbs.)
Battery weight
0.21 kg (0.47 lbs.)
Camera size (L × W × H)
245 × 166 × 164 mm (9.6 × 6.5 × 6.4 in.)
Battery size (L × W × H)
141 × 43 × 28 mm (5.5 × 1.7 × 1.1 in.)
Battery charger size (L × W × H)
158 × 122 × 25 mm (6.2 × 4.8 × 1.0 in.)
Tripod mounting
UNC ¼"-20
Housing material
Aluminum, magnesium, silicone
#T810169; r. AN/42241/42268; en-US
73
Summary of Contents for GFx320
Page 1: ...User s manual FLIR GFx3xx series...
Page 2: ......
Page 3: ......
Page 5: ...User s manual FLIR GFx3xx series T810169 r AN 42241 42268 en US v...
Page 6: ......
Page 92: ...Mechanical drawings 25 See next page T810169 r AN 42241 42268 en US 80...
Page 95: ...EU Declaration of conformity 26 See next page T810169 r AN 42241 42268 en US 83...
Page 96: ......
Page 97: ...MET Compliance Data Report truncated 27 See next page T810169 r AN 42241 42268 en US 85...
Page 100: ...IEC IECEE Intertek Test Report truncated 28 See next page T810169 r AN 42241 42268 en US 88...
Page 102: ......
Page 103: ...IEC IECEE Intertek CB Test Certificate 29 See next page T810169 r AN 42241 42268 en US 91...
Page 104: ......
Page 105: ......
Page 106: ...MET Laboratories Test Certificate truncated 30 See next page T810169 r AN 42241 42268 en US 94...
Page 108: ...MET Laboratories Letter of Certification 31 See next page T810169 r AN 42241 42268 en US 96...
Page 163: ......