16.3.2
Explanation of the adjustment methods
Auto
An adjustment method that will automatically adjust the image for best brightness
and contrast.
HSM
HSM = High Sensitivity Mode.
An adjustment method that is specifically designed for gas detection applications.
Working in this mode, you can change the sensitivity to optimize the image quality.
Manual
An adjustment method where you manually set the suitable temperature level and
temperature span according to the temperature of the objects in the scene.
For gas detection applications, this mode lets you center on the temperatures
around the background of the gas, so as to make the gas appear more clearly.
16.3.3
Procedure (
Auto
)
Follow this procedure to adjust an image using the
Auto
method:
1. Turn the mode wheel to
or
.
2. Push the
A/M
button to select
Auto
. The image will now be continuously adjusted for
best image brightness and contrast.
16.3.4
Figure
This figure shows the
HSM
slider:
16.3.5
Procedure (
HSM
)
Follow this procedure to adjust an image using the
HSM
method:
1. Turn the mode wheel to
or
.
2. Push the
A/M
button to select
HSM
. To change the sensitivity, move the joystick left/
right.
You will need to experiment with this setting until you get a clear image of a verified
gas leak.
16.3.6
Procedure (
Manual
)
Follow this procedure to adjust an image using the
Manual
method:
1. Turn the mode wheel to
or
.
2. Push the
A/M
button to select
Manual
, then do one of the following:
• To change the temperature level, move the joystick up/down.
• To change the temperature span, move the joystick left/right.
16.4
Selecting a suitable temperature range
16.4.1
About temperature ranges
16.4.1.1
General
The camera has three different types of ranges. Within each type of range, there are sev-
eral subranges. You must choose a suitable range for your object.
#T810169; r. AN/42241/42268; en-US
44
Summary of Contents for GFx320
Page 1: ...User s manual FLIR GFx3xx series...
Page 2: ......
Page 3: ......
Page 5: ...User s manual FLIR GFx3xx series T810169 r AN 42241 42268 en US v...
Page 6: ......
Page 92: ...Mechanical drawings 25 See next page T810169 r AN 42241 42268 en US 80...
Page 95: ...EU Declaration of conformity 26 See next page T810169 r AN 42241 42268 en US 83...
Page 96: ......
Page 97: ...MET Compliance Data Report truncated 27 See next page T810169 r AN 42241 42268 en US 85...
Page 100: ...IEC IECEE Intertek Test Report truncated 28 See next page T810169 r AN 42241 42268 en US 88...
Page 102: ......
Page 103: ...IEC IECEE Intertek CB Test Certificate 29 See next page T810169 r AN 42241 42268 en US 91...
Page 104: ......
Page 105: ......
Page 106: ...MET Laboratories Test Certificate truncated 30 See next page T810169 r AN 42241 42268 en US 94...
Page 108: ...MET Laboratories Letter of Certification 31 See next page T810169 r AN 42241 42268 en US 96...
Page 163: ......