March 10, 2019
38
Accessing the CM-330X via a Web Browser
CM-3304/CM-3308 User and Installation Guide
5.3.1.2.4 Basic Operations
The
Basic Operations
screen is used for the following functions:
·
Setting the TV format
·
Importing settings from another unit
·
Exporting settings to another unit
·
Rebooting the camera
·
Restoring partial factory defaults
·
Restoring full factory defaults
Figure 42: Basic Operations Screen
Click
Reboot
to save configured settings.
Click
Partial factory defaults
to restore factory defaults, but retain network settings (IP address, netmask
address, and gateway address), TV format, and image rotation settings. If a Basic Video Analytics license
was in use, it is saved..
Click
Full factory defaults
to restore factory defaults, including original network settings.
Caution:
Selecting
Full factory defaults
causes the camera to lose all network settings.
Attention:
Sélection par
Défaut Complet d'Usine
entraîne la caméra de perdre tous les paramètres réseau.
To select the TV format
1.
Select
Basic Configuration > Basic Operations
. The
Basic Operations
screen is displayed.
2.
From the drop-down list, select
NTSC
or
PAL
. The default is
NTSC
.
To import a setting
3.
Click
Browse
to select the file.
4.
Click
Import
to upload the file.
To export a setting
5.
Click
Export
. An information bar opens.