12
6 installation of Flexit SPiRit K2 R
Flexit SPIRIT K2 R is designed for installation in the kitchen
above the cooker, see Fig. 11. The unit is supplied in left and
right-hand versions depending on what suits duct locations
best (Chap. 5.1).
The unit must be wall-hung from a mounting bracket (Fig. 8)
at the top using the enclosed screws. It must also be screwed
to the wall at the bottom edge of the unit. Remove 2 plastic
plugs to access the mounting holes. For secure mounting, it is
necessary to use extra nailing strips (noggins). The location
of these is shown in Fig. 8.
NB! The wall must have good sound insulation, see Chap. 6.4.
The wall must be completely flat behind the ventilation unit.
If the kitchen hood area is tiled, a suitable liner plate must be
mounted behind the unit. The distance between the bottom
of the grease filter and the cooker should be at least 50 cm
for electric cookers and 65 cm for gas cookers. For the
external dimensions of the unit, see the dimensioned drawing
in Chap. 5.1.
6.1 installing the volume hood
For fitter
A ( 1 : 1 )
A
1
2
3
3
1
2
Fig. 9
1. Mount the two sides.
2. Attach the two angles.
3. Fix the glass profile.
Fig. 10
Fig. 11
596 mm
B=2mm
B=2mm
fixing, top edge
40 mm
720 mm
min 600 mm
spikerslag
gips
steinull
min 500(650) mm
Fig. 8
fixing lower edge
40 mm
720 mm
min 600 mm
spikerslag
gips
steinull
min 500(650) mm
Recommended
500mm*
*min. req. 650mm for gas cookers
Min. req. 450mm
gypsum
studs
rockwool