19
For fitter
12 Adjusting the Kitchen Hood
If basic ventilation is desired via the kitchen hood, the
damper from the factory must be replaced. Replace it with a
damper with adjustment options. This is not supplied with the
unit.
12.1 Forced Ventilation
The unit has 4 forced ventilation options:
1. (Switch on front of unit.) This gives a half-open damper
which will increase the air volume passing through the hood.
2. Turn the knob to position 2. This gives a fully open
damper which will allow even more air through the kitchen
hood.
3. Turn the knob to position 3. This will give a fully-open
damper which will allow even more air through the kitchen
hood, in that the fans go to speed 3.
4. The air volume through the unit can also be increased by
setting the fans to speed 3 via the control panel (external
panel). See separate instructions.
The damper needs closing again manually. There is no timer
in the damper. Closed in position O.
The air entering the unit through the kitchen hood does not
pass through the rotary heat exchanger (by-pass).