Flexit Roomie Dual Assembly And Operation Instructions Manual Download Page 4

4

R O O M I E   D U A L

!

•  Read the user’s manual carefully prior to 

installing and operating the unit.

•  Fulfil the user’s manual requirements as well 

as the provisions of all the applicable local 
and national construction, electrical and 
technical norms and standards.

•  The warnings contained in the user’s 

manual must be considered most seriously 
since they contain vital personal safety 
information.

•  Failure to follow the rules and safety 

precautions noted in this user’s manual may 
result in an injury or unit damage.

•  After a careful reading of the manual, keep it 

for the entire service life of the unit.

•  While transferring the unit the User’s manual 

must be turned over to the receiving 
operator. 

SAFETY REQUIRE-
MENTS

!

CAUTION! When a text bears this 
symbol, it means that personal injury 
or serious damage to the equipment 
may result if the instructions are not 
followed.

 

NB! When a text bears this symbol, 

damage to equipment or poor 
efficiency may be the consequence 
of not following the instructions.

The user’s manual consisting of the technical details, 
operating instructions and technical specification applies 
to the installation and mounting of the single-room energy 

recovery reversible ventilator Roomie Dual (hereinafter 
referred to as «the unit»).

This appliance may be used by children of 8 years or above or 
by persons with reduced sensory capacity or reduced physical 
or mental capacity, or by persons with lacking experience or 
knowledge, provided they have received instructions in the safe 
use of the appliance or are supervised to ensure safe use and 
providing they are aware of the risks.

The product is not suitable for use by children. Children must not 
be allowed to play with the appliance. Children must not carry 
out cleaning or maintenance without supervision.

Our products are subject to continuous development and we 
therefore reserve the right to make changes.

We also disclaim liability for any printing errors that may occur.

The right to give notice of lack of conformity 
applies to this product in accordance with the 
existing terms of sale, provided that the product is 
used correctly and maintained.
Filters are consumables.

The symbol on the product shows that this product must not 
be treated as household waste. It must be taken to a collec-
tion point for recycling electrical and electronic equipment.
By ensuring correct disposal of the equipment, you will 
contribute to preventing negative consequences for the 
environment and health that incorrect handling may entail. 
For further information on recycling of this product, please 
contact your local authority, your refuse collection company 
or the company from which you purchased it.

Notice of lack of conformity as a result of incorrect or 
defective installation must be submitted to the installation 
company responsible. The right to give notice of lack of 
conformity may lapse if the system is used incorrectly or 
maintenance is grossly neglected.

Summary of Contents for Roomie Dual

Page 1: ...Roomie Dual 116027EN 05 2020 03 Assembly and Operation Instructions Heat recovery single room reversible ventilation unit ART NR 115999...

Page 2: ...2 R O O M I E D U A L...

Page 3: ...ivery set 6 3 Technical data 6 4 Product desciption 8 5 Mounting and set up 10 6 Connection to power mains and control 14 7 Technical maintenance 22 8 Troubleshooting 24 9 Storage and transportation r...

Page 4: ...physical or mental capacity or by persons with lacking experience or knowledge provided they have received instructions in the safe use of the appliance or are supervised to ensure safe use and provid...

Page 5: ...ut the installation and maintenance operations with wet hands Do not operate the unit outside the temperature range stated in the user s manual Do not operate the unit in aggressive or explosive envir...

Page 6: ...s evaporation of chemicals sticky substances brous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic ge...

Page 7: ...h Roomie Dual 280 500 Front panel Outer ventilation hood Air duct length 235 71 285 207 85 137 138 Roomie Dual Overall dimensions of the indoor unit mm Standard duct is 500 mm which can be cut to min...

Page 8: ...objects to the ventilator Unit design Air ow separators Designed for separation of supply and exhaust air streams Outer ventilation hood Prevents ingress of water and foreign objects into the ventilat...

Page 9: ...as three operation modes Regeneration One of the fans of the ventilator operates in extract mode and the other one in supply mode The fans change their rotation direction every 70 seconds Ventilation...

Page 10: ...very The air duct end must protrude for the distance that enables installation of the outer ventilation hood 0 3 mm min 3 mm Insert the air duct into the wall as shown in the picture on the left Insta...

Page 11: ...of the master plate with respect to the horizon line it is recommended to use a builder s level Then mark the fastening holes for installation of the sup plied dowels and drill the holes to a required...

Page 12: ...e wall with the screws supplied with the mounting kit of the ventilator Insert the wires under the cable clamp and connect the socket connector to the circuit board The mark must be directed upwards R...

Page 13: ...ators in the air duct until it bumps up the cartridge Mark the last air ow separator to be ush with the air duct face remove it from the air duct and cut the exces sive part of the last air ow separat...

Page 14: ...from underneath the unit to the back Any connections in the terminal according to the wiring diagram Cable clamp Cable clamp The unit is rated for connection to single phase AC 100 240 V 50 60 Hz pow...

Page 15: ...tible with the unit When this is activated the ventilator switches to high speed The ventilators can be connected in series and in parallel with a central control by the master ventilator In case of i...

Page 16: ...L N L In Gnd Gnd Out NO1 NO2 12V Power input 100 240 V 50 60 Hz to the next ventilator Master Slave 1 Slave N Master Slave 1 Slave N N L N L In Gnd Gnd Out NO1 NO2 12V N L N L In Gnd Gnd Out NO1 NO2...

Page 17: ...llowed The switch position enables deactivation of the unit with the button on the side control panel 1 Turning the unit off is forbidden The switch position disables deactivation of the unit with the...

Page 18: ...Function 3 4 5 Humidity control is OFF 3 4 5 Humidity setpoint 40 3 4 5 Humidity setpoint 50 3 4 5 Humidity setpoint 60 3 4 5 Humidity setpoint 70 3 4 5 Humidity setpoint 80 Position Function 6 7 Tim...

Page 19: ...ce is follows low medium high speed Off Turning unit ON OFF Speed selection Regeneration mode In this mode the fans rotation direction changes to opposite every 70 seconds This operation mode enables...

Page 20: ...ir ow separator by pulling one of the side clamps Install the front part of the front panel and press it gently to close the air duct The fan turns off automatically The unit functionality is not chan...

Page 21: ...e Alarm indicator of the Master unit indicates an alarm in the network of the connected ventilation units Its blinking indicates shutdown of a speci c ventilation unit in the network In case of an eme...

Page 22: ...s Uplift it with a at screw driver of a respective size Disconnect the socket from the circuit board Do not pull the wires Use a at screwdriver to disconnect the socket UP Never remove the control boa...

Page 23: ...ct the Seller Some dust may accumulate on the heat exchanger block even in case of regular maintenance of the lters Clean the regenerator regularly to ensure its high heat recovery ef ciency Vacuum cl...

Page 24: ...n the screws of the ventilator or the outer ventilation hood 9 Storage and transportation regulations Store the unit in the manufacturer s original packing box in a dry closed ventilated premise with...

Page 25: ...er States relating to electromagnetic compatibility Producer VENTILATION SYSTEMS PrJSC 1 Mikhaila Kotzubinskogo St Kiev 01030 Ukraine Type Single room ventilators Roomie One Wi Roomie Dual Roomie Dual...

Page 26: ...26 R O O M I E D U A L...

Page 27: ...27 R O O M I E D U A L...

Page 28: ...Flexit AS Televeien 15 N 1870 rje www exit no...

Reviews: