17
R O O M I E D U A L
Ventilator set-up
1234567
8
Open the rubber plug
DIP-switch under
the plug
Prior to operating set up the ventilator using the DIP-switch.
It is located on the controller circuit board. To access the
DIP-switch take off the front panel of the indoor unit and
uplift the rubber plug that covers the switch.
Position
Function
1
Turning the unit off is allowed.
The switch position enables deactivation of the unit with the button on the side control panel.
1
Turning the unit off is forbidden.
The switch position disables deactivation of the unit with the button on the side control panel.
Boost mode setup.
When the humidity sensor or the external relay is triggered, one of two operation algorithms starts.
Position
Function
2
In this position the ventilator runs in the extract mode at the third speed (both fans run in
the extract mode).
2
In this position the ventilator switches to maximum speed without changing the operation
mode.