6 Mounting
PIOX R721
6.1 Transmitter
21
UMPIOX_F72xV1-3EN, 2021-09-01
6.1
Transmitter
6.1.1
Opening and closing the housing
6.1.1.1
Opening
• Loosen the screws of the transmitter housing.
• Open the housing cover of the transmitter.
6.1.1.2
Closing
Transmitter with stainless steel housing
• Close the housing cover.
• Tighten the screws of the transmitter housing with a max. torque of 1 Nm.
Caution!
Possible danger by opening the equipment at improper ambient conditions
Open the transmitter in safe ambient conditions only (e.g., air humidity < 90 %, no conductive pollution, no
explosive atmosphere). Otherwise, additional protective measures have to be taken.
Important!
Do not use objects which may damage the housing gasket to open the housing cover.
Fig. 6.1:
Transmitter
1 – screws
1