background image

Installation, Operation, & Maintenance Guide

Vantage Series

 

www.flexaseal.com 

 

Vermont 

800.426.3594 

Brazil 

55.11.3736.737

Louisiana 

225.484.0007 

Texas 

832.804.7424 

Flexaseal Engineered Seals and Systems, LLC (hereinafter referred to as "FAS") warrants that new goods manufactured 

by FAS 

(with the exception of "wear parts" or consumables all of which are not warranted) will be free from defects in 

material and workmanship (the “Warranty”). The Warranty shall be in effect for a period of the earlier of three (3) months 

from the date of installation or six (6) months from the date of shipment from FAS’s facility (which date of shipment shall 

not be greater than thirty (30) days after receipt of notice that the goods are ready to ship) (the “Warranty Period”).

 

FAS 

shall, at its option and expense, either repair, replace, or refund amounts paid for any goods that fail to conform to the 

Warranty. In no case shall FAS be obligated to remove the defective goods or install the replaced or repaired goods, and 

the end user shall be responsible for providing ready access to the goods and areas for warranty work, and all other 

associated costs, including, but not limited to, service costs, shipping fees, and expenses. FAS shall have complete 

discretion as to the method or means of repair or replacement. The end user’s failure to comply with FAS’s repair or 

replacement  directions  shall  constitute  a  waiver  of  its  rights  and  render  all  warranties  void.  Any  goods  repaired  or 

replaced under the Warranty are warranted only for the balance of the Warranty Period on the goods that were repaired 

or replaced. The Warranty is conditioned on the end user giving written notice to FAS of any goods that fail to meet the 

Warranty  within  ten  (10)  days  of  the  date  when  any  defects  first  become  apparent.  FAS  shall  have  no  warranty 

obligations to the end user with respect to any goods or parts of a good that: (a) have been repaired by parties other than 

FAS or without FAS’s written approval; (b) have been subject to misuse, misapplication, neglect, alteration, accident, or 

physical  damage;  (c)  have  been  used  in  a  manner  contrary  to  FAS’s  instructions  for  installation,  operation  and 

maintenance;  (d)  have  been  damaged  from  ordinary  wear  and  tear,  corrosion,  or  chemical  attack;  (e)  have  been 

damaged  due  to  abnormal  conditions,  vibration,  failure  to  properly  prime,  or  operation  without  flow;  (f)  have  been 

damaged due to a defective power supply or improper electrical protection; or (g) have been damaged resulting from the 

use of accessory Products not sold by FAS or not approved by FAS in connection with goods supplied by FAS. 

THE  FOREGOING  WARRANTY  IS  EXCLUSIVE  AND  IN  LIEU  OF  ANY  AND  ALL  OTHER  EXPRESS,  ORAL,  OR 

IMPLIED WARRANTIES, GUARANTEES, CONDITIONS OR TERMS OF WHATEVER NATURE RELATING TO THE 

GOODS  PROVIDED  HEREWITH,  INCLUDING  WITHOUT  LIMITATION,  ANY  IMPLIED  WARRANTIES  OF 

MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR  PURPOSE,  WHICH  ARE  HEREBY  EXPRESSLY 

DISCLAIMED  AND  EXCLUDED.  END  USER’S  EXCLUSIVE  REMEDY  AND  FAS’S  AGGREGATE  LIABILITY  FOR 

BREACH  OF  ANY  OF  THE  FOREGOING  WARRANTIES  ARE  LIMITED  TO  THE  REPAIR,  REPLACEMENT,  RE-

PERFORMANCE, OR REFUND. 

IN NO EVENT SHALL FAS’S LIABILITY ARISING OUT OF OR IN ANY WAY RELATED TO THE GOODS EXCEED 

THE AMOUNT PAID BY END USER UNDER THIS AGREEMENT. FAS SHALL HAVE NO LIABILITY FOR LOSS OF 

PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS OF BUSINESS, LOSS OF 

PRODUCTION, LOSS OF OPPORTUNITY, LOSS OF USE, LOSS OF REPUTATION, BUSINESS INTERRUPTION, 

DOWNTIME, INDIRECT, CONSEQUENTIAL, INCIDENTAL, PUNITIVE OR EXEMPLARY DAMAGES, HOWSOEVER 

ARISING,  WHETHER  IN  WARRANTY,  CONTRACT,  TORT,  PRODUCT  LIABILITY,  STRICT  LIABILITY,  OR 

OTHERWISE, REGARDLESS OF WHETHER FAS HAS BEEN APPRISED OF THE POSSIBILITY OF SUCH LOSSES 

IN ADVANCE.

This warranty and limitation of liability shall be governed and construed in accordance with the laws of the State of 

Delaware, USA.  Sole and exclusive venue for any claim or controversy arising out of or in any way related to  this 

warranty and limitation of liability shall be in a state court located in Chittenden County, Vermont, USA.  

FAS SW

 

V

2.2020

LIMITED WARRANTY AND LIMITATION OF LIABILITY: 

SEAL PRODUCTS 

Page 10 of 10

Summary of Contents for VANTAGE Series

Page 1: ...Avenue Houston Williston VT 05495 Bom Retiro Sao Paulo Gonzales LA 70737 7545 E Orem Drive Brazil CEP 01130 010 Houston TX 77075 TEL 832 804 7424 TEL 802 878 8307 TEL 55 11 3736 7373 TEL 225 484 0007...

Page 2: ...al installation operation and maintenance must only be carried out by qualified personnel who have thoroughly read all instructions 3 The seal must only be used for its intended application Flexaseal...

Page 3: ...e shaft shaft sleeve if present and seal chamber face of rust burrs grit sharp edges and set screw damage using fine emery cloth Wipe clean Avoid making flat spots or reducing the shaft diameter 4 If...

Page 4: ...nout 0 0015 0 003 in Fig 3 Radial bearing fit 0 002 0 003 in Fig 4 Bearing frame perpendicularity 0 0005 in in Fig 5 Axial shaft movement end play 0 003 in Fig 6 Seal chamber bore concentricity 0 005...

Page 5: ...ket facing but clear of the seal chamber 6 Reassemble the pump as described by the pump OEM 7 If the gland is equipped with a gland gasket lubricate gland bolts and bolt the gland to the seal chamber...

Page 6: ...RUE AS APPLICABLE TO EACH OTHER WITHIN 002 TOTAL INDICATOR READING UNLESS OTHERWISE SPECIFIED DATE 5 15 2020 A UNLESS OTHERWISE SPECIFIED DECIMALS 005 FRACTIONS 015 ANGLES 1 2 REMOVE ALL BURRS CHAMFER...

Page 7: ...gland Figure 12 The recomended port connection locations are dependent on the direction of rotation of the equipment The gland ports are numbered for reference Figure 11 Piping should slope continuous...

Page 8: ...5 FRACTIONS 015 ANGLES 1 2 REMOVE ALL BURRS CHAMFER ALL CORNERS 010 020 X 45 A GLAND MATERIAL 316 SS CF8M DESIGNED BY CHECKED BY JOB NO GEN V Port 2 Buffer Barrier Fluid In Clockwise Rotation Port 1 P...

Page 9: ...NCE If leakage is detected it should be addressed as soon as possible to protect personnel and prevent hazards Leakage could come from a number of leak paths in the seal or be caused by changes in the...

Page 10: ...ins and hazardous products must be reiterated Make note of all fluids contained in the pump drain and decontaminate before opening the housing for seal service 1 Ensure all fluid has been drained and...

Page 11: ...ject to misuse misapplication neglect alteration accident or physical damage c have been used in a manner contrary to FAS s instructions for installation operation and maintenance d have been damaged...