Output Load Transient Response, Default Configuration
Output voltage response to load current step-
change (12.5-37.5-12.5 A) at:
T
P1
= +25 °C, V
I
= 12 V, V
O
= 1.0 V
di/dt=2 A/µs, f
sw
= 320 kHz, C
O
= 470 µF/10 mΩ
Default configuration (DLC and default NLR)
Top trace: output voltage (200 mV/div.).
Bottom trace: load current (10 A/div.).
Time scale: (0.1 ms/div.).
Output Load Transient Response, DLC and No NLR
Output voltage response to load current step-
change (12.5-37.5-12.5 A) at:
T
P1
= +25 °C, V
I
= 12 V, V
O
= 1.0 V
di/dt=2 A/µs, f
sw
= 320 kHz, C
O
= 470 µF/10 mΩ
DLC and no NLR
Top trace: output voltage (200 mV/div.).
Bottom trace: load current (10 A/div.).
Time scale: (0.1 ms/div.).
Output Load Transient Response, DLC and Optimized NLR
Output voltage response to load current step-
change (12.5-37.5-12.5 A) at:
T
P1
= +25 °C, V
I
= 12 V, V
O
= 1.0 V
di/dt=2 A/µs, f
sw
= 320 kHz, C
O
= 470 µF/10 mΩ
DLC and optimized NLR
Top trace: output voltage (200 mV/div.).
Bottom trace: load current (10 A/div.).
Time scale: (0.1 ms/div.).
BMR4
6
series
PoL Regulators
Input 4.5-14 V, Output up to 50 A / 165 W
1/28701-BMR 464 Rev.B
July 2019
© Flex
Technical Specification
BMR4
6
series
PoL Regulators
Input
4.5-14
V, Output up to
50
A
/
165
W
1/28701-BMR 464 Rev.B
July 2019
©
Flex
Technical Specification
59