Flex-Pro Norprene A3 Operating Manual Download Page 5

3.0

Features

Enclosure Rating:

NEMA 4X:

  Constructed for either indoor or outdoor use to provide a degree of protection to personnel against 

incidental contact with enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, 
windblown dust, splashing water, and hose-directed water; and that will be undamaged by external formation of ice 
on enclosure.

IP66:

  No ingress of dust; complete protection against contact. Water projected in powerful jets against enclosure from 

any direction shall have no harmful effects.

Page 5

!

!

!

!

!

!

!

!

!

!

!

!

Peristaltic pump design does not have valves that can clog requiring maintenance.

Self priming - even against maximum line pressure. By-pass valves are not required. Cannot vapor lock or 
lose prime.

2500:1 turndown ratio. 

SCADA Inputs include: 4-20mA, 0-10Vdc, and Pulse inputs for remote external speed control and 0-30 VDC / 
contact closure remote start/stop.

Operator friendly digital touch pad with menu driven software.

VGA Graphic multi-color backlit LCD displays remote/local control status, motor speed, output rate, input 
signal values, service and alarm status.

Outputs include: Scalable 4-20mA or pulse, one 250V/6A relay and three 115V/1A contact closures assignable 
to monitor up to 17 different pump functions including TFD, FVS, remote/local control setting, motor on, fault, 
current operating mode, and others.

Two CNC precision machined squeeze rollers and two alignment rollers for optimum squeeze, unparalleled 
accuracy, and tube life.

Heavy duty rotor - single piece plastic rotor means no flexing and increased accuracy (no metal springs or 
hinges to corrode).

Inject at maximum PSI in either direction (clockwise and counter clockwise).

!

Output rates to: 171 GPH (648 LPH) and pressures to 125 PSI (8.6 Bar).

!

No maintenance brushless variable speed motor.

!

Specially engineered tubing for long life at high pressures.

!

Patented Tube Failure Detection (TFD) system. Senses tube failure by detecting chemical in the pump head. 
No false triggering.

Patent pending feature for extended tube life.

Compatible with Blue-White’s output Flow Verification Sensor (FVS) system. 

3.1

Agency Listings

Symbol

Explanation

!

WARNING, risk of electric shock

CAUTION, refer to users’ guide

GROUND, PROTECTIVE CONDUCTOR TERMINAL

Flex-Pro

This pump is ETL listed to conforms to the following:

UL Standard 778 as a motor operated water pump
CSA Standard C22.2 as process control equipment

This pump complies to the Machinery Directive 98/37/EC, BS EN 60204-1, Low Voltage Directive 
73/23/EC BS EN 61010-1, EMC Directive 89/336/EC, BS EN 50081-1/BS EN 50082-1.

Summary of Contents for Norprene A3

Page 1: ...e co id or info spe co id URL www spe co id SERIES A3V and A4V Operating Manual ProSeries by Blue White Ind TM Patents 7 001 153 7 284 964 4 496 295 and other patents pending FLEX PRO Peristaltic Mete...

Page 2: ...onal Dosing 24 10 0 Contact Closure Input 25 11 0 Set FVS flow verification system 26 12 0 Output Setup Signal Relay Contact Closure 27 12 1 Signal Output 28 13 0 Pump Tube Timer 29 14 0 TFD tube fail...

Page 3: ...C 130 54 130 54 F C 130 54 130 54 130 54 130 54 F C 185 85 185 85 185 85 185 85 185 85 Norprene A3 Tube Pumps Meets FDA criteria for food Excellent chemical resistance Extra long life at low pressures...

Page 4: ...15 1 4 D 20 6W x 27 3H x 38 9D cm A4 models 12 1 8 W x 14 1 4 H x 18 5 8 D 30 8W x 36 1H x 47 3D cm Approximate shipping wt A3 models 33 lb 15 0 Kg A4 models 56 lb 25 4 Kg Wetted components Non Wette...

Page 5: ...15V 1A contact closures assignable to monitor up to 17 different pump functions including TFD FVS remote local control setting motor on fault current operating mode and others Two CNC precision machin...

Page 6: ...nly n Raise metering pump 4 1 2 inches 11 43 cm off ground or a surface n Made out of tough Stainless Steel n Provides a stable mounting surface Stainless Steel extended brackets allow pump to be secu...

Page 7: ...buildup when injecting chemicals that calcify such as sodium hypochlorite Duckbill may add additional back pressure to pump up to 7 psi 3 8 OD x 1 4 ID Tubing and Tri Clamp connection Models Proper ey...

Page 8: ...and power cables together Power Interruption This pump has an auto restart feature which will restore pump to operating state it was in when power was lost Note When in doubt regarding your electrical...

Page 9: ...CE ACTIVE LOOP OPEN COLLECTOR 0 1000 Hz 50 DUTY CYCLE 6 AMP MAX AT 250 VAC 5 AMP MAX AT 30 VOLT DC 1 AMP MAX AT 125 VOLT AC 0 8 AMP MAX AT 30 VOLT DC 1 AMP MAX AT 125 VOLT AC 0 8 AMP MAX AT 30 VOLT DC...

Page 10: ...a runtime function and is also used when configuring your pump Runtime Function While pump is operating in any Run Mode you can view useful information regarding your current Run Mode by pressing RIG...

Page 11: ...until STOP or START button is pressed STOP button will stop pump and display will read OFF START button will stop prime feature and jump back into previous operating state To REVERSE ROTATION of rotor...

Page 12: ...ist of all available options Scroll bar example While making a selection where only one choice is allowed you will see a radio button Radio button example In a screen where you are making changes you...

Page 13: ...lay Language Esc Reset to Defaults Set Password Display Rate Reset to Factory Defaults Reset to Factory Defaults Reset to Factory Defaults Are you sure Yes No Liter Hr Gal Hr US Gal day US Done Displa...

Page 14: ...Display Rate Press MENU button to enter menu structure for setting up pump Select Configuration and Press ENTER button Select Display Rate and Press ENTER button Select your desired Display Rate unit...

Page 15: ...fault setting is DISABLE Set FVS Flow Verification System Set Flow Verification time delay Use this feature if you are using a Blue White flow verification sensor to monitor flow output Default settin...

Page 16: ...nu structure To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed Tip This feature can be combined with Contact Input feature to allow for remote Start...

Page 17: ...t Esc at bottom of every screen menu until you see Run Mode screen displayed 4 20 mA Input Motor Min Signal Input Motor Speed at Minimum mA Signal 00 0 0 4 20 mA Input Min mA Signal Input Min mA signa...

Page 18: ...ture To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed 0 10 VDC Input Motor Min Signal Input Motor Speed at Minimum Volt DC Signal 00 0 0 0 10 VDC I...

Page 19: ...ency Input setup you must navigate back out of menu structure To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed Frequency Input Motor Min Signal Inp...

Page 20: ...hold Select Run Mode button until Run Mode screen is displayed If you used Menu button to navigate to Pulse Batch setup you must navigate back out of menu structure To do this you must select Esc at...

Page 21: ...setup then just press and hold Select Run Mode button until Run Mode screen is displayed If you used Menu button to navigate to Cycle Adjustment setup you must navigate back out of menu structure To...

Page 22: ...arrow to scroll through 0 9 on selected digit Press RIGHT arrow to scroll over to next digit to right If you pass your desired digit you can easily scroll back by continuously pressing RIGHT button P...

Page 23: ...desired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save changes Continue this process until all four screens have been configured If you used short cut to e...

Page 24: ...easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Continue this process until all four screens have been configured If you used short cut to enter Proportional D...

Page 25: ...croll down to Done selection Then press ENTER To navigate back out of menus select Esc and press the ENTER button at bottom of every screen menu until you see Run Mode screen displayed IMPORTANT If Co...

Page 26: ...d during stopper operation such as with chlorine an alarm delay time value from 1 255 seconds must be programmed An alarm delay value of 000 seconds disables FVS system If FVS alarm occurs pump will s...

Page 27: ...ontact 1 Contact 2 Contact 3 Esc Relay Output 4 20 mA Output Signal min Motor Input mA Signal Min Motor speed 4 20 mA Output Minimum Motor Input Min Motor for mA Signal Output 4 20 mA Output Signal Ma...

Page 28: ...mA 100 Pump Output 20 mA Signal Output Frequency Output Disable Done 4 20 mA Output Default 4 20 mA output settings shown Signal Output Disable Done 4 20 mA Output Default Frequency Hz output settings...

Page 29: ...14 0 TFD Tube Failure Detection Flex Pro is equipped with a Tube Failure Detection System which is designed to stop pump and provide an output alarm see Output menu in the event pump tube should rupt...

Page 30: ...Stop pump by pressing STOP button Thoroughly clean Pump Head and Rotor Rotor can be removed by pulling straight out After cleaning process push Rotor back on shaft See drawing above for proper assembl...

Page 31: ...to slide discharge fitting into pump head tongue and groove Once discharge fitting is secured in pump head stop pump by pressing STOP button Replace pump head cover Pump will ask you if you d like to...

Page 32: ...Page 32 This Page Blank Flex Pro...

Page 33: ...Page 33 This Page Blank Flex Pro...

Page 34: ...Page 34 This Page Blank Flex Pro...

Page 35: ...to allow back flow If your desire is to simply extend tube life Typically tubing fails on outlet side pressure side of tube assembly in pump head Failure to install checkvalves in their proper flow d...

Page 36: ...mical from pump Determine which parts are being attacked and replace them with parts that have been manufactured using more suitable materials Manufacturer does not assume responsibility for damage to...

Page 37: ...ller assemblies rotors in this group are same size and interchangeable Tubing in this group are interchangeable Norprene Group All roller assemblies rotors in this group are same size and interchangea...

Page 38: ...Tubing ID Example Tube Assembly reorder number with NH printing A3 SNH T A 3 S N H T Pump Series Tubing Material N Norprene T Norprene Chemical G Tygothane Tubing ID D 075 E 125 F 155 G 187 H 250 J 3...

Page 39: ...tested with water only for pressure and performance Installers and operators of these devices must be well informed and aware of the precautions to be taken when injecting various chemicals especiall...

Reviews: