1.1      Available Models

Flex-Pro

A3 Models

®

Tygothane  A3 Tube Pumps 

Meets FDA criteria for food  |  Resistant to oils, greases and fuels

GPH

.002 - 4.6

.004 - 10.1
.010 - 24.9

.011 - 28.5

LPH

.007 - 17.4
.015 - 38.4
.038 - 94.2

.043 - 

ML/Min

.1 - 290
.3 - 637

.6 - 1570
.7 - 1800

 RPM

125
125
125
125

115V AC

A3V24-*GE

A3V24-*GG
A3V24-*GH

A3V24-*GK

 230V AC

A3V25-*GE

A3V25-*GG
A3V25-*GH

A3V25-*GK

 220V AC

A3V26-*GE

A3V26-*GG
A3V26-*GH

A3V26-*GK

®

Norprene  Chemical A3 Tube Pumps  

Meets FDA criteria for food  |  Superior chemical resistance

LPH

.022 - 55.1

.043 - 108.0

 230V AC

A3V25-*TH
A3V25-*TK

115V AC

A3V24-*TH
A3V24-*TK

GPH

.006 - 14.5

.011 - 28.5

 220V AC

A3V26-*TH
A3V26-*TK

ML/Min

.4 - 920

.7 - 1800

 RPM

125
125

®

Norprene  A3 Tube Pumps 

Meets FDA criteria for food  |  Excellent chemical resistance  |  CIP   |  SIP

LPH

.026 - 66.0
.038 - 96.0

.050 - 126

.003 - 7.8

 230V AC

A3V25-*ND
A3V25-*NH

A3V25-*NK

A3V25-*NJ

115V AC

A3V24-*ND
A3V24-*NH

A3V24-*NK

A3V24-*NJ

GPH

.007 - 17.4
.010 - 25.3
.013 - 33.3

.001 - 2.10

 220V AC

A3V26-*ND
A3V26-*NH

A3V26-*NK

A3V26-*NJ

ML/Min

.
.4 - 1097
.6 - 1596
.8 - 2100

05 - 132

Feed Rate

 RPM

125
125
125
125

Max

Speed

A3   Model Numbers

 PSI (bar)

65 (

)

65 (

)

65 (

)

4.5
4.5
4.5

65 (4.5)

Max

Pressure

 PSI (bar)

125 (8.6)
125 (8.6)
125 (8.6)
125 (8.6)

 PSI (bar)

50 (3.4)
50 (3.4)

LPH

.04 - 108
.07 - 168
.09 - 219
.15 - 378
.24 - 600

 230V AC

A4V25-*NH

A4V25-*NJ

A4V25-*NL

A4V25-*NP

A4V25-*NK

115V AC

A4V24-*NH

A4V24-*NJ

A4V24-*NL

A4V24-*NP

A4V24-*NK

GPH

.01 - 28.5 
.02 - 44.4
.02 - 57.8

.04 - 100.0
.06 - 158.5

 220V AC

A4V26-*NH

A4V26-*NJ

A4V26-*NL

A4V26-*NP

A4V26-*NK

ML/Min

.7 - 1800

1.1 - 2800
1.5 - 3200
2.5 - 6300

4.0 - 10000

 RPM

125
125
125
125
125

 PSI (bar)

125 (8.6)
100 (6.9)
100 (6.9)

50 (3.4)
30 (2.0)

Max

Temperature

 F (C)

185 (85)
185 (85)
185 (85)
185 (85)

 F (C)

130 (54)
130 (54)

 F (C)

130 (54)
130 (54)
130 (54)
130 (54)

 F (C)

185 (85)
185 (85)
185 (85)
185 (85)
185 (85)

®

Norprene  A3 Tube Pumps 

Meets FDA criteria for food  |  Excellent chemical resistance  |  Extra long life at low pressures

LPH

.050 - 126

 230V AC

A3V25-*NKL

115V AC

A3V24-*NKL

GPH

.013 - 33.3

 220V AC

A3V26-*NKL

ML/Min

.8 - 2100

 RPM

125

 PSI (bar)

30 (2.1)

 F (C)

185 (85)

A4 Models

®

Tygothane  A4 Tube Pumps 

Meets FDA criteria for food  |  Resistant to oils, greases and fuels

GPH

.01 - 34.8
.02 - 58.6

LPH

.05 - 132
.09 - 222

ML/Min

.9 - 2200

1.5 - 3700

 RPM

125
125

115V AC

A4V24-*GH
A4V24-*GK

 230V AC

A4V25-*GH
A4V25-*GK

 220V AC

A4V26-*GH
A4V26-*GK

®

Norprene  Chemical A4 Tube Pumps  

Meets FDA criteria for food  |  Superior chemical resistance

LPH

.03 - 78

.06 - 162

 230V AC

A4V25-*TH
A4V25-*TK

115V AC

A4V24-*TH
A4V24-*TK

GPH

.01 - 20.6
.02 - 42.8

 220V AC

A4V26-*TH
A4V26-*TK

ML/Min

.5 - 1300

1.1 - 2700

 RPM

125
125

®

Norprene  A4 Tube Pumps 

Meets FDA criteria for food  |  Excellent chemical resistance  |  CIP   |  SIP

Feed Rate

Max

Speed

A4   Model Numbers

 PSI (bar)

65 (

)

65 (

)

4.5
4.5

Max

Pressure

 PSI (bar)

30 (2.1)
30 (2.1)

Max

Temperature

 F (C)

130 (54)
130 (54)

 F (C)

130 (54)
130 (54)

®

Norprene  A4 Tube Pumps 

Meets FDA criteria for food  |  Excellent chemical resistance  |  Extra long life at low pressures

LPH

.07 - 192

 230V AC

A4V25-*NKL

115V AC

A4V24-*NKL

GPH

.02 - 50.7

 220V AC

A4V26-*NKL

ML/Min

1.3 - 3200

 RPM

125

 PSI (bar)

30 (2.1)

 F (C)

185 (85)

* Inlet/outlet connection type
S = 3/8” OD x 1/4” ID tubing compressions type connections
M = 1/2”male NPT
B = 1/2” ID tubing barb type connections (available on A4 models only)
C-= 3/4” tri-clamp connections

!

The Flex-Pro Peristaltic Pump’s output is linear over the entire 0.05% to 100% 

adjustment range. 

!

Output versus pressure is nearly linear in all models. Larger tubes exhibit greater 

losses.

!

For optimum tube life, specify the pump so that it operates at the lowest possible RPM 

Summary of Contents for Norprene A3

Page 1: ...e co id or info spe co id URL www spe co id SERIES A3V and A4V Operating Manual ProSeries by Blue White Ind TM Patents 7 001 153 7 284 964 4 496 295 and other patents pending FLEX PRO Peristaltic Mete...

Page 2: ...onal Dosing 24 10 0 Contact Closure Input 25 11 0 Set FVS flow verification system 26 12 0 Output Setup Signal Relay Contact Closure 27 12 1 Signal Output 28 13 0 Pump Tube Timer 29 14 0 TFD tube fail...

Page 3: ...C 130 54 130 54 F C 130 54 130 54 130 54 130 54 F C 185 85 185 85 185 85 185 85 185 85 Norprene A3 Tube Pumps Meets FDA criteria for food Excellent chemical resistance Extra long life at low pressures...

Page 4: ...15 1 4 D 20 6W x 27 3H x 38 9D cm A4 models 12 1 8 W x 14 1 4 H x 18 5 8 D 30 8W x 36 1H x 47 3D cm Approximate shipping wt A3 models 33 lb 15 0 Kg A4 models 56 lb 25 4 Kg Wetted components Non Wette...

Page 5: ...15V 1A contact closures assignable to monitor up to 17 different pump functions including TFD FVS remote local control setting motor on fault current operating mode and others Two CNC precision machin...

Page 6: ...nly n Raise metering pump 4 1 2 inches 11 43 cm off ground or a surface n Made out of tough Stainless Steel n Provides a stable mounting surface Stainless Steel extended brackets allow pump to be secu...

Page 7: ...buildup when injecting chemicals that calcify such as sodium hypochlorite Duckbill may add additional back pressure to pump up to 7 psi 3 8 OD x 1 4 ID Tubing and Tri Clamp connection Models Proper ey...

Page 8: ...and power cables together Power Interruption This pump has an auto restart feature which will restore pump to operating state it was in when power was lost Note When in doubt regarding your electrical...

Page 9: ...CE ACTIVE LOOP OPEN COLLECTOR 0 1000 Hz 50 DUTY CYCLE 6 AMP MAX AT 250 VAC 5 AMP MAX AT 30 VOLT DC 1 AMP MAX AT 125 VOLT AC 0 8 AMP MAX AT 30 VOLT DC 1 AMP MAX AT 125 VOLT AC 0 8 AMP MAX AT 30 VOLT DC...

Page 10: ...a runtime function and is also used when configuring your pump Runtime Function While pump is operating in any Run Mode you can view useful information regarding your current Run Mode by pressing RIG...

Page 11: ...until STOP or START button is pressed STOP button will stop pump and display will read OFF START button will stop prime feature and jump back into previous operating state To REVERSE ROTATION of rotor...

Page 12: ...ist of all available options Scroll bar example While making a selection where only one choice is allowed you will see a radio button Radio button example In a screen where you are making changes you...

Page 13: ...lay Language Esc Reset to Defaults Set Password Display Rate Reset to Factory Defaults Reset to Factory Defaults Reset to Factory Defaults Are you sure Yes No Liter Hr Gal Hr US Gal day US Done Displa...

Page 14: ...Display Rate Press MENU button to enter menu structure for setting up pump Select Configuration and Press ENTER button Select Display Rate and Press ENTER button Select your desired Display Rate unit...

Page 15: ...fault setting is DISABLE Set FVS Flow Verification System Set Flow Verification time delay Use this feature if you are using a Blue White flow verification sensor to monitor flow output Default settin...

Page 16: ...nu structure To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed Tip This feature can be combined with Contact Input feature to allow for remote Start...

Page 17: ...t Esc at bottom of every screen menu until you see Run Mode screen displayed 4 20 mA Input Motor Min Signal Input Motor Speed at Minimum mA Signal 00 0 0 4 20 mA Input Min mA Signal Input Min mA signa...

Page 18: ...ture To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed 0 10 VDC Input Motor Min Signal Input Motor Speed at Minimum Volt DC Signal 00 0 0 0 10 VDC I...

Page 19: ...ency Input setup you must navigate back out of menu structure To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed Frequency Input Motor Min Signal Inp...

Page 20: ...hold Select Run Mode button until Run Mode screen is displayed If you used Menu button to navigate to Pulse Batch setup you must navigate back out of menu structure To do this you must select Esc at...

Page 21: ...setup then just press and hold Select Run Mode button until Run Mode screen is displayed If you used Menu button to navigate to Cycle Adjustment setup you must navigate back out of menu structure To...

Page 22: ...arrow to scroll through 0 9 on selected digit Press RIGHT arrow to scroll over to next digit to right If you pass your desired digit you can easily scroll back by continuously pressing RIGHT button P...

Page 23: ...desired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save changes Continue this process until all four screens have been configured If you used short cut to e...

Page 24: ...easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Continue this process until all four screens have been configured If you used short cut to enter Proportional D...

Page 25: ...croll down to Done selection Then press ENTER To navigate back out of menus select Esc and press the ENTER button at bottom of every screen menu until you see Run Mode screen displayed IMPORTANT If Co...

Page 26: ...d during stopper operation such as with chlorine an alarm delay time value from 1 255 seconds must be programmed An alarm delay value of 000 seconds disables FVS system If FVS alarm occurs pump will s...

Page 27: ...ontact 1 Contact 2 Contact 3 Esc Relay Output 4 20 mA Output Signal min Motor Input mA Signal Min Motor speed 4 20 mA Output Minimum Motor Input Min Motor for mA Signal Output 4 20 mA Output Signal Ma...

Page 28: ...mA 100 Pump Output 20 mA Signal Output Frequency Output Disable Done 4 20 mA Output Default 4 20 mA output settings shown Signal Output Disable Done 4 20 mA Output Default Frequency Hz output settings...

Page 29: ...14 0 TFD Tube Failure Detection Flex Pro is equipped with a Tube Failure Detection System which is designed to stop pump and provide an output alarm see Output menu in the event pump tube should rupt...

Page 30: ...Stop pump by pressing STOP button Thoroughly clean Pump Head and Rotor Rotor can be removed by pulling straight out After cleaning process push Rotor back on shaft See drawing above for proper assembl...

Page 31: ...to slide discharge fitting into pump head tongue and groove Once discharge fitting is secured in pump head stop pump by pressing STOP button Replace pump head cover Pump will ask you if you d like to...

Page 32: ...Page 32 This Page Blank Flex Pro...

Page 33: ...Page 33 This Page Blank Flex Pro...

Page 34: ...Page 34 This Page Blank Flex Pro...

Page 35: ...to allow back flow If your desire is to simply extend tube life Typically tubing fails on outlet side pressure side of tube assembly in pump head Failure to install checkvalves in their proper flow d...

Page 36: ...mical from pump Determine which parts are being attacked and replace them with parts that have been manufactured using more suitable materials Manufacturer does not assume responsibility for damage to...

Page 37: ...ller assemblies rotors in this group are same size and interchangeable Tubing in this group are interchangeable Norprene Group All roller assemblies rotors in this group are same size and interchangea...

Page 38: ...Tubing ID Example Tube Assembly reorder number with NH printing A3 SNH T A 3 S N H T Pump Series Tubing Material N Norprene T Norprene Chemical G Tygothane Tubing ID D 075 E 125 F 155 G 187 H 250 J 3...

Page 39: ...tested with water only for pressure and performance Installers and operators of these devices must be well informed and aware of the precautions to be taken when injecting various chemicals especiall...