![FLENDER LOHER DYNAVERT L05 Series Commissioning And Maintenance Instructions Download Page 51](http://html1.mh-extra.com/html/flender-loher/dynavert-l05-series/dynavert-l05-series_commissioning-and-maintenance-instructions_2303823051.webp)
DYNAVERT
®
L05
Annex
4BS0516DE-EN/011
Stand/ issue: 25.07.03
51
7.1.2 Parameter
menu
P-OPERATION
Display-text
Menu
Description
Value
1)
Range
Language
Commis.
Actual
language
........ (“German”,”English”)
A
Commis.
Application
........
(“ ... ”)
2)
Menu
Commis.
Visible parameter level
........
(“ ... ”)
3)
Date
Stand.
Actual date
........
( xx.xx.xx )
Time
Stand. Actual
time
........
( xx:xx:xx )
P-TRAVEL CURVE DATA
v 1
Stand.
Intermediate speed v1
........
(0,02 ... 5,00 (m/s)
v 2
Stand.
Intermediate speed v2
........
(0,02 ... 5,00 (m/s)
v 3
Commis.
Rated speed v3
........
(0,02 ... 5,00 (m/s)
v 4
Exp.
Intermediate speed v4
........
(0,02 ... 5,00 (m/s)
v 5
Exp.
Intermediate speed v5
........
(0,02 ... 5,00 (m/s)
v 6
Exp.
Intermediate speed v6
........
(0,02 ... 5,00 (m/s)
v 7
Exp.
Intermediate speed v7
........
(0,02 ... 5,00 (m/s)
v 8
Exp.
Intermediate speed v8
........
(0,02 ... 5,00 (m/s)
v Posi
Commis.
Positioning
speed
........
(0,02 ... 0,20 m/s)
v N
Stand.
Relevelling speed
........
(0,005 ... 0,300 m/s)
v R
Stand.
Revision speed
........
(0,02 ... 1,25 m/s)
v K
Exp.
Minimum speed (end of travel)
........
(0,001 ... 0.020 m/s)
BrkDis 1
Stand.
Braking distance from v1
........
0,5 ... 3000 cm)
BrkDis 2
Stand.
Braking distance from v2
........
(0,5 ... 3000 cm)
BrkDis 3
Commis.
Braking distance from v3
........
(0,5 ... 3000 cm)
BrkDis 4
Exp.
Braking distance from v4
........
0,5 ... 3000 cm)
BrkDis 5
Exp.
Braking distance from v5
........
(0,5 ... 3000 cm)
BrkDis 6
Exp.
Braking distance from v6
........
(0,5 ... 3000 cm)
BrkDis 7
Exp.
Braking distance from v7
........
0,5 ... 3000 cm)
BrkDis 8
Exp.
Braking distance from v8
........
(0,5 ... 3000 cm)
StopDist
Commis.
Stopping
distance
........
(0,5 ... 3000 cm)
Position
Commis.
Positioning
distance
........
(0,0 ... 30,0 cm)
Flushness
Exp.
Level position
........
(0,0 ... 5,0 mm)
Ogival run
Stand. Ogival
run
........
(“no”/”yes”)
Adjust.run
Stand. Adjustment
run
........ (”StopDist”/“Trvl.Crv”)
Accel.
Commis.
Acceleration
........
(0,25 ... 2,00 m/s
2
)
Decel.
Commis.
Deceleration
........
(0,25 ... 2,00 m/s
2
)
Jerk 1
Stand.
Acceleration increase 1 starting action
........
(0,10 ... 2,50 m/s
3
)
Jerk 2
Stand.
dto. 2 prior to reaching rated speed
........
(0,10 ... 2,50 m/s
3
)
Jerk 3
Stand.
dto. 3 start of deceleration
........
(0,30 ... 2,50 m/s
3
)
Jerk 4
Stand.
dto. 4 prior to reaching positioning speed ........
(0,30 ... 2,50 m/s
3
)
Jerk 56
Stand.
dto. 5 prior to levelling speed to zero
........
(0,20 ... 2,50 m/s
3
)
P-MONITORING
v-level
Stand. Levelling
speed
........
(0,03 ... 0,55 m/s)
v max
Commis.
Maximum
speed
........
(0,03 .... 5,50 m/s)
v N max
Stand.
max. Relevelling speed
........
(0,03 ... 0,330 m/s)
v R max
Stand.
max. Revision speed
........
(0,03 ... 1,40 m/s)
Store v max exc Exp.
Fault memory excess speed
........
(“no”/”yes”)
v decel.
Stand. Deceleration
speed
........
(0,20 ... 5,00 m/s)
Store v decel.
Exp.
Fault memory deceleration monitoring
........
(“no”/”yes”)
Setp/actv.dev Exp.
admissible deviation setpoint/actual value ........
(5 ... 30 %)
Store setp/actv
Exp.
Fault memory deviation setpoint/actual value.......
(“no ”/”yes”)
Store inv.overt
Exp.
Fault memory inverter excess temperature ........
(“no ”/” yes ”)
Store mot.overt
Exp.
Fault memory motor excess temperature
........
(“no ”/” yes ”)
Delay PTC
Stand.
Delay thermistor tripping
........
(0 ... 99 s)
Store not ready
Exp.
Fault memory “not-ready”-fault
........
(“no”/” yes ”)
Note:
1) Actual setting values to be entered
2) Parameterisable applications are, for example “
asynchron HTL1024
”,
“
synch.SAD ERN1387
”, “
asynchron DCP Res
”, “
synch.SAD DCP Res
”
and “
specific
” (set of parameters was chanched manually)
3) Possible menu entries “
Commissioning
”, “
Standard
”, “
Expert
”