APPLIANCE DATA
Main injector (1 off)
Bray Elbow size 420, Cat 82
Pilot Type.
Copreci Single Flame
Type
21100 / 161
Max. Gross Heat Input :
6.6 kW
Min. Gross Heat Input :
2.0 kW
Cold Pressure :
20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition :
Battery Ignition, 1.5V
Electrode Spark Gap :
4.0 mm
Weight (Packed) :
21.5 kg
Supply Voltage
230V ac, 50Hz
Fuse Rating
3 Amp
Mains Cable
1 x 1.8M PVC 1mm2
Illumination
2 x 60W BC Fireglow Bulb
Firebox Dimensions (with case fitted)
Width :
715mm
Height : (without feet fitted)
680mm
Depth :
300mm
Height to top of the flue spigot : 420mm
Gas Connection :
8mm compression
(Supplied with fire)
Efficiency Declaration
The efficiency of this appliance has been measured as specified in BS 7977-1 :
2009 + A1 : 2013 and the result after conversion to Gross using the appropriate
factor from Table 4 of SAP 2009 is 66.7%.
The test data from which it has been calculated has been certified by BSI.
The efficiency value may be used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings.
3