d)
Remove the valve retaining nut as shown below and disconnect the
wires to the microswitch as shown on page 18, Fig. 12
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
a)
Remove the front panel and front bezel as described in section 4.2
b)
Unscrew the pilot fixing screws. These can be accessed from the front
of the appliance with the front panel and bezel removed.
c)
Remove the thermocouple as described in section 4.3. (d)
4.5
REMOVAL / REPLACEMENT OF THE RADIANTS
Remove the radiants by lifting them slightly then pulling forward as shown
in fig. 13 below.
Fig. 13
19