SECTION 2
INSTALLATION OF FIRE
2.1 UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully from the front of
the appliance.
IMPORTANT:
THE CARDBOARD FITMENT THAT IS AT THE TOP OF THE
CONVECTION APERTURE SHOULD NOT BE REMOVED UNTIL THE
APPLIANCE IS FULLY INSTALLED AND READY TO BE LIT.
DO NOT UNDER ANY CIRCUMSTANCES USE THIS APPLIANCE IF THE GLASS PANEL
IS BROKEN OR NOT SECURELY FIXED TO THE FIREBOX.
Check the contents as listed: -
Packing Check List
1off
Fire box / burner assembly
1off
Fascia Assembly & Ashpan Cover
1off
Flue Terminal unit
– pack 2 of 2
1off
Loose Items pack
– containing :-
1 off Flue pipe gasket
4 off No.12 x 65mm fixing screws
15 off No.8 x 10mm fixing screws
4 off rawplugs
1 off 6mm Allen Key
1off Right Hand Supply Pipe
1off cable fixing kit
1 off heat deflector plate
2.2 FIRE PLACE OPENING
The front opening of the fireplace must be between 410 and 420mm wide, and between 550 and
560mm high. If the opening exceeds these dimensions then a surround must be constructed from
suitable non-combustible material to produce a suitable sized opening. Any surround must be
suitably sealed to the wall or fireplace to prevent leakage. See fig.3
Fig. 3
550min, 560max
410min
420max
480min
Minimum flat
sealing area
620min
Fire opening