Using the screws and gaskets provided, fit both inner and outer flue pipes to the firebox.
(See figure 7 )
Using mortar or sealing compound, seal the outer flue pipe to the outside surface of the
wall, (See sketch on the page 11 for position of mortar).
Fig. 7
NOTE: 12 Screws are provided, six off to affix the inner flue pipe and six off to affix
the outer flue pipe, (3 off to secure flue terminal to outer flue pipe).
Spigot
Outer flue
Inner flue