To fit using the
preferred
cable method
proceed as follows: -
f)
Mark out and drill 3 off No 14 (6mm) holes in the back face of the fire opening in the positions
shown in fig.11.
Fig. 11
g) Fit the wallplugs provided and screw the fixing eyes securely into the rear of the fire opening.
h) Uncoil the two fire fixing cables and thread one end of each of the cables through each of the
two holes on each side of the convection air aperture. The holes are located behind the top
glass frame mounting brackets.
i)
Position the fire carefully on the (protected) surface of the hearth and reach into the fire
opening. Thread each of the cables vertically downwards around each side of the flue and
through the fixing eye in the centre of the wall. Thread the free end of the cables through the
circular hole on lower centre rear of the fire. Carefully slide the firebox back into the fire
opening whilst threading both the cables through the hole at the bottom centre of the fire.
Then thread both the cables through the bracket on the R/H/S of the fire and pull both cables
tight.
j) Thread the cables through the bracket on the R/H/S of the convection air aperture. Thread a
tensioning screw over both of the cables and ensure that the tensioning nut is screwed fully up
against the hexagon shoulder of the tensioning screw. (This provides maximum travel for the
tensioning nut).
k) Fit a screwed nipple on to each of the cables and pull hand tight up against the tensioning
screw, then secure each nipple with a flat bladed screwdriver. See fig. 12.
l) Tighten the tensioning screw.
500
20
250
Fire opening
Hearth
Hole positions