JX 5600

User manual

Release 1.24

This document is subject to modification without notice

Please, if necessary, ask for new release at : [email protected]

FLA

SH

EL

EK

Summary of Contents for JX 5600

Page 1: ...EK 2007 17 rue Marcel Sembat F 21000 DIJON JX 5600 User manual Release 1 24 This document is subject to modification without notice Please if necessary ask for new release at contact flashelek com FLA...

Page 2: ...9 4 1 Machine level 9 4 1 1 ASCII mode 9 4 1 2 ModBus Jbus mode 11 4 1 2 1 Querying the JX5600 11 4 1 2 2 Answer from the JX5600 12 4 1 2 3 Error trapping 12 4 2 Human level 13 4 3 Web site 14 4 3 1...

Page 3: ...uch as described underneath The Power Station supplies the sets with main 240V AC 10 Black wire on diagram The mains cable has to be able to supply 0 5 rms A 220 V AC or 1 rms A 110 V AC for each flas...

Page 4: ...ms duration This flash is the Master His internal clock pilots the repetition period of the whole SFLS Power Station JX 5600 This flash is the Master Its internal clock pilots the repetition period of...

Page 5: ...nnector Jbus connections It is necessary to connect a J Bus Load on each end of line to insure a perfect impedance for the digital signal 3 J Bus Loads are delivered with eachJX 56001 1 If you need sp...

Page 6: ...set via analog way see JX2360 Connection manual for details JX 5600 Rear panel connector Analog connections To switch on the sets short circuit ON and GND When ON to change brilliance levels short cir...

Page 7: ...14 66 or 266 ms 1 3 Querying the Flash sets The JX 5600 may query the sets for The present brightness set up Wether a lamp operates or not curative maintenance The number of flashes a lamp has done s...

Page 8: ...local mode or reconnect remote mode the server On local mode the SFLS may be switched of and off directly via a harware switch on the panel This mode allows the maintenance engineer to over drive the...

Page 9: ...with a semicolon Query Answer ACTIVE_MESSAGE SFLC_STATUS0X010Y0a0a 0j Where X 0 on local mode 1 on remote mode Y 0 when SFLS is Off 1 when SFLS in On and LI active 2 when SFLS in On and MI active 3 wh...

Page 10: ...e and interflash intervall delay on the whole SFLS X 0 for 500 ms period 1 for 1 s period 2 for 1 5 s period 3 for 2 s period Y 0 for 0 ms delay 1 for 14 ms delay 2 for 66 ms delay 3 for 266 ms delay...

Page 11: ...box 0x11 Lan error 4 1 2 1 Querying the JX5600 The skeleton of query frame is as follow aa aa 00 00 00 0b FF Is the Modbus header where aa aa is the transaction number You can fill it as you want the...

Page 12: ...Modbus protocol 00 0b shows the following bytes quantity 0xFF or 0x01 takes place of module adress This is unused as JX5600 IP adress is known and unique Followed by the content of the answer which ca...

Page 13: ...g on a situation where there are many For example naming a JX 5600 25L will let the title of the pages become Supervision 25L If DHCP mode is activated then you can navigate to http 25L Nevertheless i...

Page 14: ...ff led is green the Flashes are Yellow The brightness level is switched on LI level LI led is green other are red The SFLS has 22 flashes The flashes number 21 and 22 are configured in REILS mode The...

Page 15: ...me the whole sytem is connected on the mains click on the button This will begin a procedure where JX 5600 knows the adress of each Flash Boxe and the emplacement in the SFLS This page also lets the r...

Page 16: ...chosen and the flash counter will appear When you change a flash lamp either in preventive or curative action you will reset the counter by resetting the clock card of the flash box To do that discon...

Page 17: ...oose or type the IP adress of the JX5600 on which you want to connect The following window appears 4 frames are present Boxes shows the state of each box Configuration parameter the SFLS Maintenance I...

Page 18: ...18 22 Configuration frame Maintenance frame...

Page 19: ...19 22 Broadcast frame...

Page 20: ...mains Let pushed the red button located on rear panel and plug again the mains during 4 seconds After at least 4 seconds the default parameters Factory settings are restored Factory settings are Seria...

Page 21: ...ws D D otherwise its shows or the adress you have given before If you need to configure back the set and you cannot do it via web pages or JX5600Pilot for any reason do as follow Unplug the mains Open...

Page 22: ...ur need of DHCP Then choose menu 0 Factory settings are Serial number 0 Be Carefull the MAC adress is made with the serial number IP adress 192 168 1 130 Gateway adress 192 168 1 1 Subnet mask 255 255...