7 / 22
1.2
Commanding the Flash sets
The JX 5600 may :
•
Switch on/off the sets
•
Select brilliance level (3% low intensity : LI,
10% medium intensity : MI
100% hight intensity : HI)
If necessary, the JX 5600 may :
•
Change the repetition period of the SFLS from 500 ms to 1 s , 1,5 s or 2 s.
•
Change the inter flash intervall delay from 0, 14, 66 or 266 ms.
1.3
Querying the Flash sets
The JX 5600 may query the sets for:
•
The present brightness set up
•
Wether a lamp operates or not (curative maintenance)
•
The number of flashes a lamp has done since the last global switch on (preventive maintenance)
•
Internal un-documented technical datas
1.4
Case of J-Bus fault
When a box do not receive any J-Bus frame during a period longer than 2mn, then it automaticaly force
its internal J-Bus command to the state OFF/Low Intensity.
Analog commands keep their action.