10 / 22
Command
Action
STEP_CONTROL
XY;
This command changes the brightness level of the whole SFLS
following XY value :
XY =
00
to switch Off the SFLS
01
to switch On on LI mode
02
to switch On on MI mode
03
to switch On on HI mode
SPEED_CONTROL
XY;
This command changes the repetition period time and interflash
intervall delay on the whole SFLS
X =
0
for 500 ms period
1
for 1 s period
2
for 1,5 s period
3
for 2 s period
Y =
0
for 0 ms delay
1
for 14 ms delay
2
for 66 ms delay
3
for 266 ms delay
CAT_CONTROL
abcdef
ghijklmnopqrstuvwxyzA
BCDEF
4
;
This command specifies each box which will really switch on when a
SFLS ON command is sent. (see STEP_CONTROL)
(This command allows to use the SFL under various standard modes)
a to F = 1 (Box will flash)
a to F = 0 (Box will not flash)
4
when 32 boxes
Summary of Contents for JX 5600