Technical specifications

H2

W2

W1

D2

D1

General
Type of protection

IP 54   

Weight

ca. 25 kg

System installation

G ½”

Feed joint at the impulse water counter

R ½”

Pipe joint drain/overflow

DN40

Volume system separation box

12 litre

System data
Supply flow pressure

1 – 10 bar

System pressure

1 – 9 bar

Volume flow

max. 210 l/h

Temperature range supply

> 0 °C – 30 °C

Electrical data
Supply voltage

230 V, 50 Hz

Power input

0,3 kW

Mains fuse

230 V, 10 A (slow)

Load capacity collective malfunction message

230 VAC, 3 A 

Influencing variables
Environmental temperature

> 0 °C – 40 °C during operation, -20 °C – 65 °C when transported and stored.

Relative humidity 

< 80% during operation, when transported and stored -> non-condensing.

Main dimensions (nominal)

H2

495 mm

W1

380 mm

W2

320 mm

D1

320 mm

D2

215 mm

Nominal diameter

Maximum line length system installation

DN15

10 m

DN20

20 m

DN25

30 m

Summary of Contents for Fill-PE

Page 1: ...Flamco www flamcogroup com TP 04 02 09 EN Edition 2009 EXP Flamco Fill PE Installation and operating instructions...

Page 2: ...emperature 3 2 6 Signs on the automat 4 3 Description 5 3 1 Component overview 5 3 2 Controller SCU 6 3 3 Working principle 6 4 Transport and storage 7 4 1 Transport 7 4 2 Storage 7 5 Installation 8 5...

Page 3: ...co shall not be liable for any losses arising from the non observance of safety conditions or as a consequence of the disregard of standard precautionary measures when performing such services as tran...

Page 4: ...mperature Permissible working overpressure zul ssiger Betriebsdruck Manufacturer No Herstell Nr Nachspeiseautomat flamco FILL PE Flamco A B C On the automat the following product information can be fo...

Page 5: ...9 3 Description 3 1 Component overview No Description 1 Inspection opening breaktank 2 Joint for pipe HT DN40 at overflow 3 Impulse water counter 4 Feed joint R 5 System joint G 6 Controller SCU with...

Page 6: ...that is stored in a breaktank The controller will switch OFF the pump after an adjustable pressure difference is reached The refill time and amount is protected and can be adjusted as welI Level contr...

Page 7: ...e pallets and are fully assembled Identify the items that are missing or not correctly delivered Read the general terms and conditions in the shipping papers Transport the pallets horizontally Lift th...

Page 8: ...ting and certification bodies prior to the launch of the system 5 2 Ambient conditions 1 m 0 5 m 1 3 1 7 m 80 0 C 40 C KW 01 2008 STAG GmbH 39307 Genthin 30 C Zulauf 10 bar max Betriebstemperatur Perm...

Page 9: ...lation line of the system and the supply line is DN 15 Connect the installation line of the system DN 40 Connect the drain overflow 5 5 Electrical installation Even if isolated from the mains there ca...

Page 10: ...ctronic control unit SDS D Flamco C A B D External e g M K U Refill 230 V External refill for potential free contact INPUT INPUT 1 3 Nominal current A unit Fuse wiring connector A Nominal voltage Prot...

Page 11: ...ressure Special system press Liter Puls Water treatment Filling quantity Time Date Other Other internal ID Number Language Litres counter Water treatment Control mode Operating mode Sensor Motor prote...

Page 12: ...on P 8 8 bar Auto Liter 100 2 sec Hold down the navigation wheel for two seconds to go to the process display whatever the cursor position P 8 8 bar Auto Liter 100 P 8 8 bar Auto Liter 100 In case of...

Page 13: ...36 00 Save 3 sec Time and date Language Zero Setting Control mode Language Filling pressure Start Back Press controlled Level controlled G5 3 Water treatment Litre pulse Special syst press F4 menu onl...

Page 14: ...be removed Release the pressure of the water compartment before maintenance 7 2 After a power failure The programmed parameters of the controller do not change after a power failure The SCU unit the...

Page 15: ...the impulse water counter Extend adjusted value for reaction time of the impulse water counter If necessary change impulse water counter 6 Pressure increase amount The pressure increase amount was ref...

Page 16: ...ly filled yet Solve leakage Check adjusted value Re activate filling mode 16 Change module Amount of the water treatment module exceeded A Module capacity of the water treatment exhausted Change modul...

Page 17: ...INSTALLATION AND OPERATING INSTRUCTIONS TP 04 02 09 EN Edition 2009 EXP 8 Disposal Comply with local legislations OFF 1 OFF 230 V 2 Make sure the system power switch is OFF Disconnect the power suppl...

Page 18: ...10 bar System pressure 1 9 bar Volume flow max 210 l h Temperature range supply 0 C 30 C Electrical data Supply voltage 230 V 50 Hz Power input 0 3 kW Mains fuse 230 V 10 A slow Load capacity collecti...

Reviews: