FKI GL 9000 Series User Manual Download Page 23

23 

 

9.4.

 

Wirering diagrams 

 

GL 9001 400V  

 
 

Pr

in

t :

1

. Udgang

ss

igna

l ak

tua

tor

2

. In

dg

ang

 24

V

DC +

3

. In

dg

an

g 24VDC -

4

. Udga

ng

ss

igna

l v

arm

ele

geme, ned

re

5

. Udga

ngs

sig

nal v

arme

lege

me, ø

vre

6. 

In

dgan

24VDC 

+

M

Summary of Contents for GL 9000 Series

Page 1: ...Users Manual Turbomatic contact grill GL 9000 series Version 2 4 SEP 2016...

Page 2: ...2...

Page 3: ...ersonal safety equipment 6 4 2 Residual risks 6 5 Operation 7 5 1 Quick guide 7 5 2 Programming 7 5 3 Locking display 8 5 4 Operating 9 5 5 Stop 9 5 6 Emergency stop 9 5 6 1 Restart efter emergency st...

Page 4: ...Knowledge It is the employer s owner of the contact grill obligation to ensure that all who serve main tain or repair the contact grill read the instructions at least those parts of it that are relev...

Page 5: ...fications and consumption Dimensions GL 9001 GL 9002 GL 9003 GL 9010 Dimension W x D x H mm 400 x 630 x 480 600 x 630 x 480 400 x 630 x 480 490 x 730 x 480 Weight 62 kg 85 kg 65 kg 95 kg Note the heig...

Page 6: ...contact grill must be placed under hoods or other suction of cooking smells 4 Safety and residual risks 4 1 Safety precautions to be taken by the user 4 1 1 Personal safety equipment It is recommended...

Page 7: ...l pro grammed Place the meat on the bottom pan and press one of the program buttons 1 3 The upper will close and the meat will fry on both sides in the pre set time as the display counts down to 0 aft...

Page 8: ...enu press Reset Factory settings Standby temp 240 C Normal temp upper pan 250 C Normal temp lower pan 240 C Program 1 130 sec Program 2 130 sec Program 3 130 sec 5 3 Locking display The display shows...

Page 9: ...ower to the contact grill turn the main switch on the back side to OFF 5 6 Emergency stop The upper pan can be stopped during movement by turning the main switch to OFF 5 6 1 Restart efter emergency s...

Page 10: ...See the technical data section 3 4 In particular if the counter top is hanging on the wall be aware that this is firmly attached and that the wall is suitable for fixing of heavy loads Note that there...

Page 11: ...blank Wipe dry with clean cloth or paper If Teflon sheet is used in the pans clean them with a damp cloth with a mild cleaning agent We recommend using Teflon sheet supplied as it prevents burn in and...

Page 12: ...k the fuse on the PCB Still no light in one display other is OK Try to connect a new keypad to check if it s the keyboard that is defec tive The plug must be installed correctly on the PCB the shiny s...

Page 13: ...13 7 3 1 Specifications on spare parts GL 9001...

Page 14: ...4 1 kW 400V 8 83 10323 1 Frontpanel incl PCB and key pad 9 83 20103 1 Electrical components see wiring diagram 10 83 09975 1 Bottom plate GL 9001 3 11 82 06510 4 Leg M8 adjustable 12 83 09980 1 Fat dr...

Page 15: ...ption 1 83 10292 1 Bottom cabinet GL 9002 2 83 10293 1 Pan GL 9002 lower 3 83 10237 1 Top cabinet large incl arm 4 83 10279 1 Pan upper large 5 83 10325 1 Top cabinet small incl arm 6 83 10324 1 Front...

Page 16: ...400V 15 83 09323 1 Heatelement upper 2 3 kW 400V 16 82 06510 4 Leg M8 adjustable 17 84 00067 1 Switch 4 polet CA 25 32A 400V 17a 84 00292 1 Handle for switch type CA 18 84 00290 1 Fuse holder 18a 84 0...

Page 17: ...17 GL 9003...

Page 18: ...Pan GL 9003 lower 8 83 09320 2 Pan upper small 9 83 09321 2 Heat element upper 2 3 kW 400V 10 83 09323 2 Heat element lower 2 6 kW 400V 11 82 06510 4 Leg M8 adjustable 12 84 00067 1 Switch 4 polet CA...

Page 19: ...19 GL 9010...

Page 20: ...mponents see wiring diagram 10 83 10323 1 Frontpanel incl PCB and key pad 11 83 10333 6 Heat element 1 85 kW 400V 12 83 10325 1 Actuator LA 23 13 83 10096 1 Adjustingbolt for pan 14 83 10336 4 Tension...

Page 21: ...h your country order This means that when the product becomes obsolete you should dispose of it after the local mu nicipality s rules for example in unsorted waste stream 9 Annex 9 1 Labels symbols an...

Page 22: ...tnr og by 5690 Tommerup Erkl rer hermed at maskine type Turbomatic GL 9001 GL 9002 GL 9003 og GL 9010 Er fremstillet i overensstemmelse med f lgende EF direktiver 2006 42 EF Maskindirektivet under anv...

Page 23: ...23 9 4 Wirering diagrams GL 9001 400V Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Page 24: ...SSR 20 265A 6 83 07563 1 Rectifyer 7 84 00294 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 1 Actuator MLA 2 9 83 09322 1 Heat element lower 4 7 kW 400V 10 83 09320 1 Heat element upper 4 1 kW 400V 11...

Page 25: ...25 GL 9002 400V M Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Page 26: ...1 Ringtransformer 230V 2x24V 80VA 8 83 10022 2 Actuator MLA 2 9 83 09322 1 Heat element lower 4 7 kW 400V 10 83 09320 1 Heat element upper 4 1 kW 400V 11 83 09057 1 Sensor PT100 upper 11a 83 09998 1...

Page 27: ...27 GL 9003 400V M Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Page 28: ...SSR 20 265A 6 83 07563 1 Rectifyer 7 84 00295 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 2 Actuator MLA 2 9 83 09323 1 Heat element lower 2 6 kW 400V 10 83 09321 1 Heat element upper 2 3 kW 400V 11...

Page 29: ...29 GL 9010 400V Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Page 30: ...7 84 00294 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 1 Actuator MLA 2 9 83 09322 6 Heat element 1 85 kW 400V 10 83 30015 1 Connection block 15 pole 11 83 09057 1 Sensor PT100 upper 11a 83 09998 1...

Page 31: ...31 Bygh jvej 5 Verninge DK 5690 Tommerup Danmark Tlf 45 6475 1066 info fki dk www fki dk...

Reviews: