FKI GL 9000 Series User Manual Download Page 18

18 

 

Pos. 

Part no. 

Pcs. 

Description 

83-09984 

Bottom cabinet GL 9003  

83-10325 

Top cabinet small incl. arm 

83-10324 

Frontpanel double incl. PCB and key-pad 

83-10022 

Actuator MLA-2 

83-20105 

Electrical components – see wiring diagram 

83-09980 

Fat drawer 

83-09296 

Pan GL 9003 lower 

83-09320 

Pan upper small 

83-09321 

Heat element upper 2,3 kW 400V 

10 

83-09323 

Heat element lower 2,6 kW 400V 

11 

82-06510 

Leg M8 adjustable 

12 

84-00067 

Switch 4-polet CA25 32 A 

12a 

84-00292 

Handle for switch 

13 

84-00290 

Fuse holder 

13a 

84-00289 

Fuse 2A 

14 

83-10195 

Cover plate upper small 

15 

83-09120 

Cover plate lower small 

16 

83-09312 

Tension piece lower 

17 

83-09329 

Tension piece upper small 

18 

83-09975 

Bottom plate GL 9001/3 

 
 

 

Summary of Contents for GL 9000 Series

Page 1: ...Users Manual Turbomatic contact grill GL 9000 series Version 2 4 SEP 2016...

Page 2: ...2...

Page 3: ...ersonal safety equipment 6 4 2 Residual risks 6 5 Operation 7 5 1 Quick guide 7 5 2 Programming 7 5 3 Locking display 8 5 4 Operating 9 5 5 Stop 9 5 6 Emergency stop 9 5 6 1 Restart efter emergency st...

Page 4: ...Knowledge It is the employer s owner of the contact grill obligation to ensure that all who serve main tain or repair the contact grill read the instructions at least those parts of it that are relev...

Page 5: ...fications and consumption Dimensions GL 9001 GL 9002 GL 9003 GL 9010 Dimension W x D x H mm 400 x 630 x 480 600 x 630 x 480 400 x 630 x 480 490 x 730 x 480 Weight 62 kg 85 kg 65 kg 95 kg Note the heig...

Page 6: ...contact grill must be placed under hoods or other suction of cooking smells 4 Safety and residual risks 4 1 Safety precautions to be taken by the user 4 1 1 Personal safety equipment It is recommended...

Page 7: ...l pro grammed Place the meat on the bottom pan and press one of the program buttons 1 3 The upper will close and the meat will fry on both sides in the pre set time as the display counts down to 0 aft...

Page 8: ...enu press Reset Factory settings Standby temp 240 C Normal temp upper pan 250 C Normal temp lower pan 240 C Program 1 130 sec Program 2 130 sec Program 3 130 sec 5 3 Locking display The display shows...

Page 9: ...ower to the contact grill turn the main switch on the back side to OFF 5 6 Emergency stop The upper pan can be stopped during movement by turning the main switch to OFF 5 6 1 Restart efter emergency s...

Page 10: ...See the technical data section 3 4 In particular if the counter top is hanging on the wall be aware that this is firmly attached and that the wall is suitable for fixing of heavy loads Note that there...

Page 11: ...blank Wipe dry with clean cloth or paper If Teflon sheet is used in the pans clean them with a damp cloth with a mild cleaning agent We recommend using Teflon sheet supplied as it prevents burn in and...

Page 12: ...k the fuse on the PCB Still no light in one display other is OK Try to connect a new keypad to check if it s the keyboard that is defec tive The plug must be installed correctly on the PCB the shiny s...

Page 13: ...13 7 3 1 Specifications on spare parts GL 9001...

Page 14: ...4 1 kW 400V 8 83 10323 1 Frontpanel incl PCB and key pad 9 83 20103 1 Electrical components see wiring diagram 10 83 09975 1 Bottom plate GL 9001 3 11 82 06510 4 Leg M8 adjustable 12 83 09980 1 Fat dr...

Page 15: ...ption 1 83 10292 1 Bottom cabinet GL 9002 2 83 10293 1 Pan GL 9002 lower 3 83 10237 1 Top cabinet large incl arm 4 83 10279 1 Pan upper large 5 83 10325 1 Top cabinet small incl arm 6 83 10324 1 Front...

Page 16: ...400V 15 83 09323 1 Heatelement upper 2 3 kW 400V 16 82 06510 4 Leg M8 adjustable 17 84 00067 1 Switch 4 polet CA 25 32A 400V 17a 84 00292 1 Handle for switch type CA 18 84 00290 1 Fuse holder 18a 84 0...

Page 17: ...17 GL 9003...

Page 18: ...Pan GL 9003 lower 8 83 09320 2 Pan upper small 9 83 09321 2 Heat element upper 2 3 kW 400V 10 83 09323 2 Heat element lower 2 6 kW 400V 11 82 06510 4 Leg M8 adjustable 12 84 00067 1 Switch 4 polet CA...

Page 19: ...19 GL 9010...

Page 20: ...mponents see wiring diagram 10 83 10323 1 Frontpanel incl PCB and key pad 11 83 10333 6 Heat element 1 85 kW 400V 12 83 10325 1 Actuator LA 23 13 83 10096 1 Adjustingbolt for pan 14 83 10336 4 Tension...

Page 21: ...h your country order This means that when the product becomes obsolete you should dispose of it after the local mu nicipality s rules for example in unsorted waste stream 9 Annex 9 1 Labels symbols an...

Page 22: ...tnr og by 5690 Tommerup Erkl rer hermed at maskine type Turbomatic GL 9001 GL 9002 GL 9003 og GL 9010 Er fremstillet i overensstemmelse med f lgende EF direktiver 2006 42 EF Maskindirektivet under anv...

Page 23: ...23 9 4 Wirering diagrams GL 9001 400V Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Page 24: ...SSR 20 265A 6 83 07563 1 Rectifyer 7 84 00294 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 1 Actuator MLA 2 9 83 09322 1 Heat element lower 4 7 kW 400V 10 83 09320 1 Heat element upper 4 1 kW 400V 11...

Page 25: ...25 GL 9002 400V M Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Page 26: ...1 Ringtransformer 230V 2x24V 80VA 8 83 10022 2 Actuator MLA 2 9 83 09322 1 Heat element lower 4 7 kW 400V 10 83 09320 1 Heat element upper 4 1 kW 400V 11 83 09057 1 Sensor PT100 upper 11a 83 09998 1...

Page 27: ...27 GL 9003 400V M Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Page 28: ...SSR 20 265A 6 83 07563 1 Rectifyer 7 84 00295 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 2 Actuator MLA 2 9 83 09323 1 Heat element lower 2 6 kW 400V 10 83 09321 1 Heat element upper 2 3 kW 400V 11...

Page 29: ...29 GL 9010 400V Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Page 30: ...7 84 00294 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 1 Actuator MLA 2 9 83 09322 6 Heat element 1 85 kW 400V 10 83 30015 1 Connection block 15 pole 11 83 09057 1 Sensor PT100 upper 11a 83 09998 1...

Page 31: ...31 Bygh jvej 5 Verninge DK 5690 Tommerup Danmark Tlf 45 6475 1066 info fki dk www fki dk...

Reviews: