3.5
Setup Menu (F4)
Below is a list of functions, which are found under the
F4
key (
Setup
menu
):
Function
Description
Line Speed
Registers the LINE SPEED used for all lines from the
current memory address forward until another Line
Speed instruction is found.
Line Dispense Setup
Registers the LINE DISPENSE SETUP values which
sets dispensing wait time at the start of lines („head‟
time), wait time at the passing points („Node‟ time) and
waiting time at the end of lines („tail‟ time). The
registered values will be used from the current memory
address forward until another Line Dispense Setup
instruction is found.
Point Dispense Setup
Registers POINT DISPENSE SETUP values, which sets
dispensing time and waiting time at the end of
dispensing („tail‟ time) for dots. The registered values will
be used from the current memory address forward until
another POINT DISPENSE SETUP instruction is found.
Dispense End Setup
Registers the height and speed the tip should raise at
the end of dispensing. The registered values will be
used from the current memory address forward until
another DISPENSE END SETUP instruction is found.
Z Clearance
Registers the additional distance the tip should rise,
beyond the height set in Dispense End Setup, to allow
obstacles to be cleared as the tip moves from one figure
to another. Values will be used until another Z Clearance
instruction is found.
XY Move Speed
Sets the movement speed of the X and Y axes when
moving from one figure to another in the program.
Z Move Speed
Sets the movement speed of the Z-axis when moving
from one figure to another in the program.
Home Position Setup
Changes the position the robot moves to at the end of a
program cycle.