7

WALL MOUNT

BACKGUARD

part no:

BGRU-3048

WALL MOUNT

BACKGUARD

part no:

BGRU2-1548

WALL MOUNT

BACKGUARD

part no:

BGRU-3048

WALL MOUNT

BACKGUARD

part no:

BGRU2-1548

WALL MOUNT

BACKGUARD

part no:

BGRU-3048

WALL MOUNT

BACKGUARD

part no:

BGRU2-1548

PRODUCT DIMENSIONS

36" MODELS

IN

MM

Overall height of range  
(from floor to cook surface, excl. pan supports and vent trim)

min 35 3/4 

max 36 3/4

min 908  

max 933

Overall width of range

35 7/8

911

Overall depth of range (excl. handle and dials)

29 1/8

740

Depth of chassis

25 3/8

644

Depth from rear of chassis to front of control panel

27 11/16

703

Height from top of cook surface to top of pan supports

1 9/16

40

Height from top of cook surface to top of 

 

z

vent trim (as illustrated)

 

z

angled vent trim (if fitted)

1 3/4
3 1/2

45

90

Height from top of cook surface to bottom of chassis

35 1/4

895

Adjustable feet height

min 1/2 

max 1 1/2

min 13 

max 38

Depth of open door to front control panel

19 1/8

486

PRODUCT DIMENSIONS – 36" MODELS

PLAN

PROFILE

FRONT

I

A

G

C

B

J

D

E

F

H

C

Summary of Contents for RDV3-304

Page 1: ...RDV3 304 RIV3 304 RDV3 366 RIV3 365 RDV3 488 RDV3 485GD RHV3 484 RDV3 486 models PROFESSIONAL RANGE INSTALLATION GUIDE US CA...

Page 2: ...any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier cal...

Page 3: ...may result in damage or personal injury Proper equipment and adequate manpower must be used in moving the range to avoid personal injury or damage to the unit or the floor The unit is heavy and rests...

Page 4: ...ian The electrician should also check that the socket cable section is suitable for the electricity drawn by the range z Service should only be done by authorized technicians Technicians must disconne...

Page 5: ...5 10 x 2 wood screws 4 Anti tip bracket 1 5 16 x 1 1 2 sleeve anchors 2 Lag bolts and washers 2 Foot cover sets 2 PARTS SUPPLIED FOR INSTALLATION...

Page 6: ...from rear of chassis to front of control panel 27 11 16 703 F Height from top of cook surface to top of pan supports 1 9 16 40 G Height from top of cook surface to top of z vent trim as illustrated z...

Page 7: ...from rear of chassis to front of control panel 27 11 16 703 F Height from top of cook surface to top of pan supports 1 9 16 40 G Height from top of cook surface to top of z vent trim as illustrated z...

Page 8: ...from rear of chassis to front of control panel 27 11 16 703 F Height from top of cook surface to top of pan supports 1 9 16 40 G Height from top of cook surface to top of z vent trim as illustrated z...

Page 9: ...Guidance dimension only Combustible covering for a ventilation hood and non combustible surface clearances are governed by local codes rather than these dimensions Non combustible surfaces as defined...

Page 10: ...Combustible RANGE RANGE MOUNT LOW BACKGUARD WALL MOUNT HIGH BACKGUARD LOW SHELF WALL MOUNT HIGH BACKGUARD HIGH SHELF BACKGUARD WIDTH INCHES MM 30 models BGRV2 1230 BGRV2 3030 BGRV3 3030H 29 7 8 759 3...

Page 11: ...hoods and blowers are designed for use with single wall ducting however some local building codes or inspectors may require double wall ducting and or a damper Consult local building codes and or agen...

Page 12: ...the two shipping bolts made visible by removing the lower guard Holding the door on both sides lift door back up to 45 and carefully pull the door out and away from the hinges Before restraining the p...

Page 13: ...the door out and away from the hinges Open the hinge locks fully on both sides Open the door completely Holding the door at 45 carefully align the hinge tongues with the hinge slots Push the door in u...

Page 14: ...ator location may vary depending on model SUPPLY AREA DIMENSIONS RIV3 MODELS IN MM A Distance from either edge of range to supply area 1 1 2 38 B Height of electrical supply area from floor 6 152 C De...

Page 15: ...z Observe all governing codes and ordinances when grounding In the absence of these codes or ordinances observe National Electrical Code ANSI NFPA No 70 current issue See the following information in...

Page 16: ...ng for the unit is to be brought into the terminal block through the conduit and through the strain relief The ends of the wiring must have 1 4 faston closed loop lugs attached Make suitable connectio...

Page 17: ...edition of National Fuel Gas Code ANSI Z 223 1 Warning this appliance must be installed by a licensed plumber or gas fitter when within the Commonwealth of Massachusetts z A manual shut off valve supp...

Page 18: ...the height Long hem edge z Ensure the doors and toe kick panel are securely in place if removed previously z Ensure any backguard is fitted prior to final positioning Refer to Backguard considerations...

Page 19: ...ty damage or serious personal injury never use a Iighted match or open flame If a leak is present tighten joint or unscrew apply more joint compound tighten again and retest connection for leak ON GAS...

Page 20: ...te drill x2 5 16 diameter pilot holes in the center of the larger holes to a depth of at least 1 3 4 3 Place the sleeve anchors into the holes and use a hammer to tap them all the way in 4 Tighten the...

Page 21: ...as shut off valve installed in an accessible location F Unit tested and free of gas leaks ELECTRICAL F Receptacle with properly rated over current protection is provided for service cord connection F...

Page 22: ...ge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications...

Reviews: