LO position (minimum rate of inner crown).
• Remove the dial.
• With a thin screwdriver, turn the regulation screw until adjustment is correct. The screw is accessible via a hole
in the microswitch.
Outside Crown of DUAL Burner (C)
• Light the DUAL burner.
• Set the gas valve to
LO position (minimum rate of outer crown and maximum rate of inner crown).
• Remove the dial.
• With a thin screwdriver, turn the regulation screw inside the tap rod until adjustment is correct.
For LP/PROPANE gas, tighten the adjustment screws completely
A
Regulation screw (Semi-Rapid burner)
B
Regulation screw (Inner crown of dual burner)
C
Regulation screw (Outer crown of dual burner)