Semi-rapid burner
Dual burner
Adjusting the Cooktop Burner Minimums
When switching from one type of gas to another, the minimum flow rate must also be correct:
• The flame should not go out even when passing suddenly from maximum to minimum flame.
To regulate the flame follow these instructions:
Semi-rapid Burner (A)
• Light the burner.
• Set the gas valve to
LO
position (minimum rate).
• Remove the dial.
• With a thin screwdriver, turn the regulation screw inside the tap rod until adjustment is correct.
Inside Crown of DUAL Burner (B)
• Light the DUAL burner.
• Set the gas valve to